Simplicity, safety, and acceptability of insulin pen use versus the conventional vial/syringe device in patients with type 1 and type 2 diabetes mellitus in Lebanon.


ABSTRACT:

Background

The aim of the study was to evaluate the simplicity, safety, patients' preference, and convenience of the administration of insulin using the pen device versus the conventional vial/syringe in patients with diabetes.

Methods

This observational study was conducted in multiple community pharmacies in Lebanon. The investigators interviewed patients with diabetes using an insulin pen or conventional vial/syringe. A total of 74 questionnaires were filled over a period of 6 months. Answers were entered into the Statistical Package for Social Sciences (SPSS) software and Excel spreadsheet. t-test, logistic regression analysis, and correlation analysis were used in order to analyze the results.

Results

A higher percentage of patients from the insulin pen users group (95.2%) found the method easy to use as compared to only 46.7% of the insulin conventional users group (P 0.001, relative risk [RR]: 2.041, 95% confidence interval [CI]: 1.178-3.535). Moreover, 61.9% and 26.7% of pen users and conventional users, respectively, could read the scale easily (P 0.037, RR 2.321, 95% CI: 0.940-5.731), while 85.7% of pen users found it more convenient shifting to pen and 86.7% of the conventional users would want to shift to pen if it had the same cost. Pain perception was statistically different between the groups. A much higher percentage (76.2%) of pen users showed no pain during injection compared to only 26.7% of conventional users (P 0.003, RR 2.857, 95% CI: 1.194-6.838).

Conclusion

The insulin pen was significantly much easier to use and less painful than the conventional vial/syringe. Proper education on the methods of administration/storage and disposal of needles/syringes is needed in both groups.

SUBMITTER: Ramadan WH 

PROVIDER: S-EPMC4383149 | biostudies-literature | 2015

REPOSITORIES: biostudies-literature

altmetric image

Publications

Simplicity, safety, and acceptability of insulin pen use versus the conventional vial/syringe device in patients with type 1 and type 2 diabetes mellitus in Lebanon.

Ramadan Wijdan H WH   Khreis Noura A NA   Kabbara Wissam K WK  

Patient preference and adherence 20150327


<h4>Background</h4>The aim of the study was to evaluate the simplicity, safety, patients' preference, and convenience of the administration of insulin using the pen device versus the conventional vial/syringe in patients with diabetes.<h4>Methods</h4>This observational study was conducted in multiple community pharmacies in Lebanon. The investigators interviewed patients with diabetes using an insulin pen or conventional vial/syringe. A total of 74 questionnaires were filled over a period of 6 m  ...[more]

Similar Datasets

| S-EPMC6732000 | biostudies-literature
| S-EPMC9314479 | biostudies-literature
| S-EPMC6723763 | biostudies-literature
| S-EPMC7283138 | biostudies-literature
| S-EPMC3638030 | biostudies-literature
| S-EPMC5899406 | biostudies-literature
| S-EPMC7669461 | biostudies-literature
| S-EPMC4496816 | biostudies-other
| S-EPMC7557978 | biostudies-literature
| S-EPMC7299891 | biostudies-literature