Unknown

Dataset Information

0

Experimental determination of the steady-state charging probabilities and particle size conservation in non-radioactive and radioactive bipolar aerosol chargers in the size range of 5-40 nm.


ABSTRACT: Three bipolar aerosol chargers, an AC-corona (Electrical Ionizer 1090, MSP Corp.), a soft X-ray (Advanced Aerosol Neutralizer 3087, TSI Inc.), and an ?-radiation-based 241Am charger (tapcon & analysesysteme), were investigated on their charging performance of airborne nanoparticles. The charging probabilities for negatively and positively charged particles and the particle size conservation were measured in the diameter range of 5-40 nm using sucrose nanoparticles. Chargers were operated under various flow conditions in the range of 0.6-5.0 liters per minute. For particular experimental conditions, some deviations from the chosen theoretical model were found for all chargers. For very small particle sizes, the AC-corona charger showed particle losses at low flow rates and did not reach steady-state charge equilibrium at high flow rates. However, for all chargers, operating conditions were identified where the bipolar charge equilibrium was achieved. Practically, excellent particle size conservation was found for all three chargers.

SUBMITTER: Kallinger P 

PROVIDER: S-EPMC4385563 | biostudies-literature | 2015

REPOSITORIES: biostudies-literature

altmetric image

Publications

Experimental determination of the steady-state charging probabilities and particle size conservation in non-radioactive and radioactive bipolar aerosol chargers in the size range of 5-40 nm.

Kallinger Peter P   Szymanski Wladyslaw W WW  

Journal of nanoparticle research : an interdisciplinary forum for nanoscale science and technology 20150405 4


Three bipolar aerosol chargers, an AC-corona (Electrical Ionizer 1090, MSP Corp.), a soft X-ray (Advanced Aerosol Neutralizer 3087, TSI Inc.), and an α-radiation-based <sup>241</sup>Am charger (tapcon & analysesysteme), were investigated on their charging performance of airborne nanoparticles. The charging probabilities for negatively and positively charged particles and the particle size conservation were measured in the diameter range of 5-40 nm using sucrose nanoparticles. Chargers were opera  ...[more]

Similar Datasets

| S-EPMC3718153 | biostudies-literature
| PRJEB11366 | ENA
| S-EPMC8873144 | biostudies-literature
| S-EPMC6312322 | biostudies-literature
| S-EPMC7380075 | biostudies-literature
| S-EPMC8296575 | biostudies-literature
| S-EPMC10512808 | biostudies-literature
| S-EPMC10994298 | biostudies-literature
| S-EPMC3785473 | biostudies-literature