Evaluating the accuracy of diffusion MRI models in white matter.


ABSTRACT: Models of diffusion MRI within a voxel are useful for making inferences about the properties of the tissue and inferring fiber orientation distribution used by tractography algorithms. A useful model must fit the data accurately. However, evaluations of model-accuracy of commonly used models have not been published before. Here, we evaluate model-accuracy of the two main classes of diffusion MRI models. The diffusion tensor model (DTM) summarizes diffusion as a 3-dimensional Gaussian distribution. Sparse fascicle models (SFM) summarize the signal as a sum of signals originating from a collection of fascicles oriented in different directions. We use cross-validation to assess model-accuracy at different gradient amplitudes (b-values) throughout the white matter. Specifically, we fit each model to all the white matter voxels in one data set and then use the model to predict a second, independent data set. This is the first evaluation of model-accuracy of these models. In most of the white matter the DTM predicts the data more accurately than test-retest reliability; SFM model-accuracy is higher than test-retest reliability and also higher than the DTM model-accuracy, particularly for measurements with (a) a b-value above 1000 in locations containing fiber crossings, and (b) in the regions of the brain surrounding the optic radiations. The SFM also has better parameter-validity: it more accurately estimates the fiber orientation distribution function (fODF) in each voxel, which is useful for fiber tracking.

SUBMITTER: Rokem A 

PROVIDER: S-EPMC4400066 | biostudies-literature | 2015

REPOSITORIES: biostudies-literature

altmetric image

Publications

Evaluating the accuracy of diffusion MRI models in white matter.

Rokem Ariel A   Yeatman Jason D JD   Pestilli Franco F   Kay Kendrick N KN   Mezer Aviv A   van der Walt Stefan S   Wandell Brian A BA  

PloS one 20150416 4


Models of diffusion MRI within a voxel are useful for making inferences about the properties of the tissue and inferring fiber orientation distribution used by tractography algorithms. A useful model must fit the data accurately. However, evaluations of model-accuracy of commonly used models have not been published before. Here, we evaluate model-accuracy of the two main classes of diffusion MRI models. The diffusion tensor model (DTM) summarizes diffusion as a 3-dimensional Gaussian distributio  ...[more]

Similar Datasets

| S-EPMC4117364 | biostudies-literature
| S-EPMC8461664 | biostudies-literature
| S-EPMC5159854 | biostudies-other
| S-EPMC6406626 | biostudies-literature
| S-EPMC7605507 | biostudies-literature
| S-EPMC4737469 | biostudies-other
| S-EPMC7652211 | biostudies-literature
| S-EPMC5716951 | biostudies-literature
| S-EPMC6548665 | biostudies-literature
| S-EPMC8202149 | biostudies-literature