Unknown

Dataset Information

0

Near-infrared fluorescent cholangiography facilitates identification of biliary anatomy during laparoscopic cholecystectomy.


ABSTRACT: Intraoperative cholangiography (IOC) is the current gold standard for biliary imaging during laparoscopic cholecystectomy (LC). However, utilization of IOC remains low. Near-infrared fluorescence cholangiography (NIRF-C) is a novel, noninvasive method for real-time, intraoperative biliary mapping. Our aims were to assess the safety and efficacy of NIRF-C for identification of biliary anatomy during LC.Patients were administered indocyanine green (ICG) prior to surgery. NIRF-C was used to identify extrahepatic biliary structures before and after partial and complete dissection of Calot's triangle. Routine IOC was performed in each case. Identification of biliary structures using NIRF-C and IOC, and time required to complete each procedure were collected.Eighty-two patients underwent elective LC with NIRF-C and IOC. Mean age and body mass index (BMI) were 42.6 ± 13.7 years and 31.5 ± 8.2 kg/m(2), respectively. ICG was administered 73.8 ± 26.4 min prior to incision. NIRF-C was significantly faster than IOC (1.9 ± 1.7 vs. 11.8 ± 5.3 min, p < 0.001). IOC was unobtainable in 20 (24.4 %) patients while NIRF-C did not visualize biliary structures in 4 (4.9 %) patients. After complete dissection, the rates of visualization of the cystic duct, common bile duct, and common hepatic duct using NIRF-C were 95.1, 76.8, and 69.5 %, respectively, compared to 72.0, 75.6, and 74.3 % for IOC. In 20 patients where IOC could not be obtained, NIRF-C successfully identified biliary structures in 80 % of the cases. Higher BMI was not a deterrent to visualization of anatomy with NIRF-C. No adverse events were observed with NIRF-C.NIRF-C is a safe and effective alternative to IOC for imaging extrahepatic biliary structures during LC. This technique should be evaluated further under a variety of acute and chronic gallbladder inflammatory conditions to determine its usefulness in biliary ductal identification.

SUBMITTER: Osayi SN 

PROVIDER: S-EPMC4415528 | biostudies-literature | 2015 Feb

REPOSITORIES: biostudies-literature

altmetric image

Publications


<h4>Background</h4>Intraoperative cholangiography (IOC) is the current gold standard for biliary imaging during laparoscopic cholecystectomy (LC). However, utilization of IOC remains low. Near-infrared fluorescence cholangiography (NIRF-C) is a novel, noninvasive method for real-time, intraoperative biliary mapping. Our aims were to assess the safety and efficacy of NIRF-C for identification of biliary anatomy during LC.<h4>Methods</h4>Patients were administered indocyanine green (ICG) prior to  ...[more]

Similar Datasets

| S-EPMC7750833 | biostudies-literature
| S-EPMC10856121 | biostudies-literature
| S-EPMC8896300 | biostudies-literature
| S-EPMC5425830 | biostudies-other
| S-EPMC8319025 | biostudies-literature
| S-EPMC5487840 | biostudies-literature
| S-EPMC5550794 | biostudies-other
| S-EPMC8523512 | biostudies-literature
| S-EPMC5533107 | biostudies-other
| PRJEB51223 | ENA