Unknown

Dataset Information

0

Multiplex serum cytokine immunoassay using nanoplasmonic biosensor microarrays.


ABSTRACT: Precise monitoring of the rapidly changing immune status during the course of a disease requires multiplex analysis of cytokines from frequently sampled human blood. However, the current lack of rapid, multiplex, and low volume assays makes immune monitoring for clinical decision-making (e.g., critically ill patients) impractical. Without such assays, immune monitoring is even virtually impossible for infants and neonates with infectious diseases and/or immune mediated disorders as access to their blood in large quantities is prohibited. Localized surface plasmon resonance (LSPR)-based microfluidic optical biosensing is a promising approach to fill this technical gap as it could potentially permit real-time refractometric detection of biomolecular binding on a metallic nanoparticle surface and sensor miniaturization, both leading to rapid and sample-sparing analyte analysis. Despite this promise, practical implementation of such a microfluidic assay for cytokine biomarker detection in serum samples has not been established primarily due to the limited sensitivity of LSPR biosensing. Here, we developed a high-throughput, label-free, multiarrayed LSPR optical biosensor device with 480 nanoplasmonic sensing spots in microfluidic channel arrays and demonstrated parallel multiplex immunoassays of six cytokines in a complex serum matrix on a single device chip while overcoming technical limitations. The device was fabricated using easy-to-implement, one-step microfluidic patterning and antibody conjugation of gold nanorods (AuNRs). When scanning the scattering light intensity across the microarrays of AuNR ensembles with dark-field imaging optics, our LSPR biosensing technique allowed for high-sensitivity quantitative cytokine measurements at concentrations down to 5-20 pg/mL from a 1 ?L serum sample. Using the nanoplasmonic biosensor microarray device, we demonstrated the ability to monitor the inflammatory responses of infants following cardiopulmonary bypass (CPB) surgery through tracking the time-course variations of their serum cytokines. The whole parallel on-chip assays, which involved the loading, incubation, and washing of samples and reagents, and 10-fold replicated multianalyte detection for each sample using the entire biosensor arrays, were completed within 40 min.

SUBMITTER: Chen P 

PROVIDER: S-EPMC4447431 | biostudies-literature | 2015

REPOSITORIES: biostudies-literature

altmetric image

Publications

Multiplex serum cytokine immunoassay using nanoplasmonic biosensor microarrays.

Chen Pengyu P   Chung Meng Ting MT   McHugh Walker W   Nidetz Robert R   Li Yuwei Y   Fu Jianping J   Cornell Timothy T TT   Shanley Thomas P TP   Kurabayashi Katsuo K  

ACS nano 20150323 4


Precise monitoring of the rapidly changing immune status during the course of a disease requires multiplex analysis of cytokines from frequently sampled human blood. However, the current lack of rapid, multiplex, and low volume assays makes immune monitoring for clinical decision-making (e.g., critically ill patients) impractical. Without such assays, immune monitoring is even virtually impossible for infants and neonates with infectious diseases and/or immune mediated disorders as access to the  ...[more]

Similar Datasets

| S-EPMC8577373 | biostudies-literature
| S-EPMC4899742 | biostudies-literature
| S-EPMC8013708 | biostudies-literature
| S-EPMC6399902 | biostudies-other
| S-EPMC8968208 | biostudies-literature
| S-EPMC7840937 | biostudies-literature
| S-EPMC4644190 | biostudies-literature
| S-EPMC6187333 | biostudies-literature
| S-EPMC3637204 | biostudies-literature
| S-EPMC7941212 | biostudies-literature