Closed-Loop Control Performance of the Hypoglycemia-Hyperglycemia Minimizer (HHM) System in a Feasibility Study.


ABSTRACT: This feasibility study investigated the insulin-delivery characteristics of the Hypoglycemia-Hyperglycemia Minimizer (HHM) System-an automated insulin delivery device-in participants with type 1 diabetes.Thirteen adults with type 1 diabetes were enrolled in this nonrandomized, uncontrolled, clinical-research-center-based feasibility study. The HHM System comprised a continuous subcutaneous insulin infusion pump, a continuous glucose monitor (CGM), and a model predictive control algorithm with a safety module, run on a laptop platform. Closed-loop control lasted approximately 20 hours, including an overnight period and two meals.When attempting to minimize glucose excursions outside of a prespecified target zone, the predictive HHM System decreased insulin infusion rates below the participants' preset basal rates in advance of below-zone excursions (CGM < 90 mg/dl), and delivered 80.4% less insulin than basal during those excursions. Similarly, the HHM System increased infusion rates above basal during above-zone excursions (CGM > 140 mg/dl), delivering 39.9% more insulin than basal during those excursions. Based on YSI, participants spent a mean ± standard deviation (SD) of 0.2 ± 0.5% of the closed-loop control time at glucose levels < 70 mg/dl, including 0.3 ± 0.9% for the overnight period. The mean ± SD glucose based on YSI for all participants was 164.5 ± 23.5 mg/dl. There were nine instances of algorithm-recommended supplemental carbohydrate administrations, and there was no severe hypoglycemia or diabetic ketoacidosis.Results of this study indicate that the current HHM System is a feasible foundation for development of a closed-loop insulin delivery device.

SUBMITTER: Finan DA 

PROVIDER: S-EPMC4454115 | biostudies-literature | 2014 Jan

REPOSITORIES: biostudies-literature

altmetric image

Publications

Closed-Loop Control Performance of the Hypoglycemia-Hyperglycemia Minimizer (HHM) System in a Feasibility Study.

Finan Daniel A DA   McCann Thomas W TW   Mackowiak Linda L   Dassau Eyal E   Patek Stephen D SD   Kovatchev Boris P BP   Doyle Francis J FJ   Zisser Howard H   Anhalt Henry H   Venugopalan Ramakrishna R  

Journal of diabetes science and technology 20140101 1


<h4>Background</h4>This feasibility study investigated the insulin-delivery characteristics of the Hypoglycemia-Hyperglycemia Minimizer (HHM) System-an automated insulin delivery device-in participants with type 1 diabetes.<h4>Methods</h4>Thirteen adults with type 1 diabetes were enrolled in this nonrandomized, uncontrolled, clinical-research-center-based feasibility study. The HHM System comprised a continuous subcutaneous insulin infusion pump, a continuous glucose monitor (CGM), and a model p  ...[more]

Similar Datasets

| S-EPMC4738202 | biostudies-literature
| S-EPMC9604572 | biostudies-literature
| S-EPMC7174034 | biostudies-literature
| S-EPMC3687268 | biostudies-literature
| S-EPMC4401751 | biostudies-literature
| S-EPMC8608837 | biostudies-literature
| S-EPMC8146235 | biostudies-literature
| S-EPMC7818334 | biostudies-literature
| S-EPMC10211393 | biostudies-literature
| S-EPMC4056360 | biostudies-literature