A Randomized, Placebo-Controlled Double-Blind Trial of a Closed-Loop Glucagon System for Postbariatric Hypoglycemia.


ABSTRACT: BACKGROUND:Postbariatric hypoglycemia (PBH) can threaten safety and reduce quality of life. Current therapies are incompletely effective. METHODS:Patients with PBH were enrolled in a double-blind, placebo-controlled, crossover trial to evaluate a closed-loop glucose-responsive automated glucagon delivery system designed to reduce severe hypoglycemia. A hypoglycemia detection and mitigation algorithm was embedded in the artificial pancreas system connected to a continuous glucose monitor (CGM, Dexcom) driving a patch infusion pump (Insulet) filled with liquid investigational glucagon (Xeris) or placebo (vehicle). Sensor/plasma glucose responses to mixed meal were assessed during 2 study visits. The system delivered up to 2 doses of study drug (300/150 ?g glucagon or equal-volume vehicle) if triggered by the algorithm. Rescue dextrose was given for plasma glucose <55 mg/dL or neuroglycopenia. RESULTS:Twelve participants (11 females/1 male, age 52 ± 2, 8 ± 1 years postsurgery, mean ± SEM) completed all visits. Predictive hypoglycemia alerts prompted automated drug delivery postmeal, when sensor glucose was 114 ± 7 vs 121 ± 5 mg/dL (P = .39). Seven participants required rescue glucose after vehicle but not glucagon (P = .008). Five participants had severe hypoglycemia (<55 mg/dL) after vehicle but not glucagon (P = .03). Nadir plasma glucose was higher with glucagon vs vehicle (67 ± 3 vs 59 ± 2 mg/dL, P = .004). Plasma glucagon rose after glucagon delivery (1231 ± 187 vs 16 ± 1 pg/mL at 30 minutes, P = .001). No rebound hyperglycemia occurred. Transient infusion site discomfort was reported with both glucagon (n = 11/12) and vehicle (n = 10/12). No other adverse events were observed. CONCLUSION:A CGM-guided closed-loop rescue system can detect imminent hypoglycemia and deliver glucagon, reducing severe hypoglycemia in PBH. CLINICAL TRIALS REGISTRATION:NCT03255629.

SUBMITTER: Mulla CM 

PROVIDER: S-EPMC7174034 | biostudies-literature | 2020 Apr

REPOSITORIES: biostudies-literature

altmetric image

Publications

A Randomized, Placebo-Controlled Double-Blind Trial of a Closed-Loop Glucagon System for Postbariatric Hypoglycemia.

Mulla Christopher M CM   Zavitsanou Stamatina S   Laguna Sanz Alejandro Jose AJ   Pober David D   Richardson Lauren L   Walcott Pamela P   Arora Ipsa I   Newswanger Brett B   Cummins Martin J MJ   Prestrelski Steve J SJ   Doyle Francis J FJ   Dassau Eyal E   Patti Mary Elizabeth ME  

The Journal of clinical endocrinology and metabolism 20200401 4


<h4>Background</h4>Postbariatric hypoglycemia (PBH) can threaten safety and reduce quality of life. Current therapies are incompletely effective.<h4>Methods</h4>Patients with PBH were enrolled in a double-blind, placebo-controlled, crossover trial to evaluate a closed-loop glucose-responsive automated glucagon delivery system designed to reduce severe hypoglycemia. A hypoglycemia detection and mitigation algorithm was embedded in the artificial pancreas system connected to a continuous glucose m  ...[more]

Similar Datasets

| S-EPMC8277203 | biostudies-literature
| S-EPMC4454115 | biostudies-literature
| S-EPMC6250632 | biostudies-literature
| S-EPMC4998932 | biostudies-other
| S-EPMC4077042 | biostudies-other
| S-EPMC4030757 | biostudies-literature
| S-EPMC8244522 | biostudies-literature
| S-EPMC5947135 | biostudies-other
| S-EPMC4822164 | biostudies-literature
2016-07-15 | GSE76003 | GEO