Unknown

Dataset Information

0

Telemetric Blood Pressure Assessment in Angiotensin II-Infused ApoE-/- Mice: 28 Day Natural History and Comparison to Tail-Cuff Measurements.


ABSTRACT: Abdominal aortic aneurysm (AAA) is a disease of the aortic wall, which can progress to catastrophic rupture. Assessment of mechanical characteristics of AAA, such as aortic distensibility, may provide important insights to help identify at-risk patients and understand disease progression. While the majority of studies on this topic have focused on retrospective patient data, recent studies have used mouse models of AAA to prospectively evaluate the evolution of aortic mechanics. Quantification of aortic distensibility requires accurate measurement of arterial blood pressure, particularly pulse pressure, which is challenging to perform accurately in murine models. We hypothesized that volume/pressure tail-cuff measurements of arterial pulse pressure in anesthetized mice would have sufficient accuracy to enable calculations of aortic distensibility with minimal error. Telemetry devices and osmotic mini-pumps filled with saline or angiotensin-II were surgically implanted in male apolipoprotein-E deficient (ApoE(-/-)) mice. Blood pressure in the aortic arch was measured continuously via telemetry. In addition, simultaneous blood pressure measurements with a volume/pressure tail-cuff system were performed under anesthesia at specific intervals to assess agreement between techniques. Compared to controls, mice infused with angiotensin-II had an overall statistically significant increase in systolic pressure, with no overall difference in pulse pressure; however, pulse pressure did increase significantly with time. Systolic measurements agreed well between telemetry and tail-cuff (coefficient of variation = 10%), but agreement of pulse pressure was weak (20%). In fact, group-averaged pulse pressure from telemetry was a better predictor of a subject's pulse pressure on a given day than a simultaneous tail-cuff measurement. Furthermore, these approximations introduced acceptable errors (15.1 ± 12.8%) into the calculation of aortic distensibility. Contrary to our hypothesis, we conclude that tail-cuff measures of arterial pulse pressure have limited accuracy. Future studies of aneurysm mechanics using the ApoE(-/-)/angiotensin-II model would be better in assuming pulse pressure profiles consistent with our telemetry findings instead of attempting to measure pulse pressure in individual mice.

SUBMITTER: Haggerty CM 

PROVIDER: S-EPMC4472759 | biostudies-literature | 2015

REPOSITORIES: biostudies-literature

altmetric image

Publications

Telemetric Blood Pressure Assessment in Angiotensin II-Infused ApoE-/- Mice: 28 Day Natural History and Comparison to Tail-Cuff Measurements.

Haggerty Christopher M CM   Mattingly Andrea C AC   Gong Ming C MC   Su Wen W   Daugherty Alan A   Fornwalt Brandon K BK  

PloS one 20150618 6


Abdominal aortic aneurysm (AAA) is a disease of the aortic wall, which can progress to catastrophic rupture. Assessment of mechanical characteristics of AAA, such as aortic distensibility, may provide important insights to help identify at-risk patients and understand disease progression. While the majority of studies on this topic have focused on retrospective patient data, recent studies have used mouse models of AAA to prospectively evaluate the evolution of aortic mechanics. Quantification o  ...[more]

Similar Datasets

2022-08-15 | PXD036063 |
2019-07-08 | GSE133015 | GEO
| S-EPMC7744531 | biostudies-literature
2009-08-26 | GSE12591 | GEO
2010-06-24 | E-GEOD-12591 | biostudies-arrayexpress
| S-EPMC6470237 | biostudies-literature
| S-EPMC4826596 | biostudies-literature
| S-EPMC7368713 | biostudies-literature
| S-EPMC7033753 | biostudies-literature
| S-EPMC3698794 | biostudies-literature