Unknown

Dataset Information

0

Microviscometry reveals reduced blood viscosity and altered shear rate and shear stress profiles in microvessels after hemodilution.


ABSTRACT: We show that many salient hemodynamic flow properties, which have been difficult or impossible to assess in microvessels in vivo, can be estimated by using microviscometry and fluorescent microparticle image velocimetry in microvessels >20 microm in diameter. Radial distributions in blood viscosity, shear stress, and shear rate are obtained and used to predict axial pressure gradient, apparent viscosity, and endothelial-cell surface-layer thickness in vivo. Based solely on microparticle image velocimetry data, which are readily obtainable during the course of most intravital microscopy protocols from systemically injected particle tracers, we show that the microviscometric method consistently predicted a reduction in local and apparent blood viscosity after isovolemic hemodilution. Among its clinical applications, hemodilution is a procedure that is used to treat various pathologies that require reduction in peripheral vascular-flow resistance. Our results are directly relevant in this context because they suggest that the fractional decrease in systemic hematocrit is approximately 25-35% greater than the accompanying fractional decrease in microvascular-flow resistance in vivo. In terms of its fundamental usefulness, the microviscometric method provides a comprehensive quantitative analysis of microvascular hemodynamics that has applications in broad areas of medicine and physiology and is particularly relevant to quantitative studies of angiogenesis, tumor growth, leukocyte adhesion, vascular-flow resistance, tissue perfusion, and endothelial-cell mechanotransduction.

SUBMITTER: Long DS 

PROVIDER: S-EPMC454164 | biostudies-literature | 2004 Jul

REPOSITORIES: biostudies-literature

altmetric image

Publications

Microviscometry reveals reduced blood viscosity and altered shear rate and shear stress profiles in microvessels after hemodilution.

Long David S DS   Smith Michael L ML   Pries Axel R AR   Ley Klaus K   Damiano Edward R ER  

Proceedings of the National Academy of Sciences of the United States of America 20040625 27


We show that many salient hemodynamic flow properties, which have been difficult or impossible to assess in microvessels in vivo, can be estimated by using microviscometry and fluorescent microparticle image velocimetry in microvessels >20 microm in diameter. Radial distributions in blood viscosity, shear stress, and shear rate are obtained and used to predict axial pressure gradient, apparent viscosity, and endothelial-cell surface-layer thickness in vivo. Based solely on microparticle image ve  ...[more]

Similar Datasets

| S-EPMC5492087 | biostudies-literature
| S-EPMC3131338 | biostudies-literature
| S-EPMC7558001 | biostudies-literature
| S-EPMC5838242 | biostudies-literature
| S-EPMC4583376 | biostudies-literature
| S-EPMC10276430 | biostudies-literature
| S-EPMC3529161 | biostudies-literature
| S-EPMC1324794 | biostudies-literature
| S-EPMC8101100 | biostudies-literature
| S-EPMC4702094 | biostudies-literature