Unknown

Dataset Information

0

Automated assessment of pain in rats using a voluntarily accessed static weight-bearing test.


ABSTRACT: The weight-bearing test is one method to assess pain in rodent animal models; however, the acceptance of this convenient method is limited by the low throughput data acquisition and necessity of confining the rodents to a small chamber.We developed novel data acquisition hardware and software, data analysis software, and a conditioning protocol for an automated high throughput static weight-bearing assessment of pain. With this device, the rats voluntarily enter the weighing chamber, precluding the necessity to restrain the animals and thereby removing the potential stress-induced confounds as well as operator selection bias during data collection. We name this device the Voluntarily Accessed Static Incapacitance Chamber (VASIC).Control rats subjected to the VASIC device provided hundreds of weight-bearing data points in a single behavioral assay. Chronic constriction injury (CCI) surgery and paw pad injection of complete Freund's adjuvant (CFA) or carrageenan in rats generated hundreds of weight-bearing data during a 30 minute recording session. Rats subjected to CCI, CFA, or carrageenan demonstrated the expected bias in weight distribution favoring the un-operated leg, and the analgesic effect of i.p. morphine was demonstrated. In comparison with existing methods, brief water restriction encouraged the rats to enter the weighing chamber to access water, and an infrared detector confirmed the rat position with feet properly positioned on the footplates, triggering data collection. This allowed hands-off measurement of weight distribution data reducing operator selection bias.The VASIC device should enhance the hands-free parallel collection of unbiased weight-bearing data in a high throughput manner, allowing further testing of this behavioral measure as an effective assessment of pain in rodents.

SUBMITTER: Kim HT 

PROVIDER: S-EPMC4586949 | biostudies-literature | 2015 Nov

REPOSITORIES: biostudies-literature

altmetric image

Publications

Automated assessment of pain in rats using a voluntarily accessed static weight-bearing test.

Kim Hung Tae HT   Uchimoto Kazuhiro K   Duellman Tyler T   Yang Jay J  

Physiology & behavior 20150721


<h4>Unlabelled</h4>The weight-bearing test is one method to assess pain in rodent animal models; however, the acceptance of this convenient method is limited by the low throughput data acquisition and necessity of confining the rodents to a small chamber.<h4>New methods</h4>We developed novel data acquisition hardware and software, data analysis software, and a conditioning protocol for an automated high throughput static weight-bearing assessment of pain. With this device, the rats voluntarily  ...[more]

Similar Datasets

| S-EPMC8427200 | biostudies-literature
| S-EPMC11355379 | biostudies-literature
| S-EPMC5600253 | biostudies-literature
| S-EPMC6810897 | biostudies-literature
| S-EPMC6375313 | biostudies-literature
| S-EPMC7286111 | biostudies-literature
| S-EPMC6706399 | biostudies-literature
| S-EPMC11310201 | biostudies-literature
| S-EPMC6594565 | biostudies-literature
| S-EPMC4485009 | biostudies-literature