Unknown

Dataset Information

0

Detecting compartmental non-Gaussian diffusion with symmetrized double-PFG MRI.


ABSTRACT: Diffusion in tissue and porous media is known to be non-Gaussian and has been used for clinical indications of stroke and other tissue pathologies. However, when conventional NMR techniques are applied to biological tissues and other heterogeneous materials, the presence of multiple compartments (pores) with different Gaussian diffusivities will also contribute to the measurement of non-Gaussian behavior. Here we present symmetrized double PFG (sd-PFG), which can separate these two contributions to non-Gaussian signal decay as having distinct angular modulation frequencies. In contrast to prior angular d-PFG methods, sd-PFG can unambiguously extract kurtosis as an oscillation from samples with isotropic or uniformly oriented anisotropic pores, and can generally extract a combination of compartmental anisotropy and kurtosis. The method further fixes its sensitivity with respect to the time dependence of the apparent diffusion coefficient. We experimentally demonstrate the measurement of the fourth cumulant (kurtosis) of diffusion and find it consistent with theoretical predictions. By enabling the unambiguous identification of contributions of compartmental kurtosis to the signal, sd-PFG has the potential to help identify the underlying micro-structural changes corresponding to current kurtosis based diagnostics, and act as a novel source of contrast to better resolve tissue micro-structure.

SUBMITTER: Paulsen JL 

PROVIDER: S-EPMC4618711 | biostudies-literature | 2015 Nov

REPOSITORIES: biostudies-literature

altmetric image

Publications

Detecting compartmental non-Gaussian diffusion with symmetrized double-PFG MRI.

Paulsen Jeffrey L JL   Özarslan Evren E   Komlosh Michal E ME   Basser Peter J PJ   Song Yi-Qiao YQ  

NMR in biomedicine 20151004 11


Diffusion in tissue and porous media is known to be non-Gaussian and has been used for clinical indications of stroke and other tissue pathologies. However, when conventional NMR techniques are applied to biological tissues and other heterogeneous materials, the presence of multiple compartments (pores) with different Gaussian diffusivities will also contribute to the measurement of non-Gaussian behavior. Here we present symmetrized double PFG (sd-PFG), which can separate these two contributions  ...[more]

Similar Datasets

| S-EPMC2997680 | biostudies-other
| S-EPMC5926247 | biostudies-literature
| S-EPMC5832256 | biostudies-literature
| S-EPMC8232758 | biostudies-literature
| S-EPMC3961541 | biostudies-literature
| S-EPMC6389825 | biostudies-literature
| S-EPMC5910247 | biostudies-literature