Unknown

Dataset Information

0

Filament Dynamics during Simulated Ventricular Fibrillation in a High-Resolution Rabbit Heart.


ABSTRACT: The mechanisms underlying ventricular fibrillation (VF) are not well understood. The electrical activity on the heart surface during VF has been recorded extensively in the experimental setting and in some cases clinically; however, corresponding transmural activation patterns are prohibitively difficult to measure. In this paper, we use a high-resolution biventricular heart model to study three-dimensional electrical activity during fibrillation, focusing on the driving sources of VF: "filaments," the organising centres of unstable reentrant scroll waves. We show, for the first time, specific 3D filament dynamics during simulated VF in a whole heart geometry that includes fine-scale anatomical structures. Our results suggest that transmural activity is much more complex than what would be expected from surface observations alone. We present examples of complex intramural activity, including filament breakup and reattachment, anchoring to the thin right ventricular apex; rapid transitions among various filament shapes; and filament lengths much greater than wall thickness. We also present evidence for anatomy playing a major role in VF development and coronary vessels and trabeculae influencing filament dynamics. Overall, our results indicate that intramural activity during simulated VF is extraordinarily complex and suggest that further investigation of 3D filaments is necessary to fully comprehend recorded surface patterns.

SUBMITTER: Pathmanathan P 

PROVIDER: S-EPMC4637469 | biostudies-literature | 2015

REPOSITORIES: biostudies-literature

altmetric image

Publications

Filament Dynamics during Simulated Ventricular Fibrillation in a High-Resolution Rabbit Heart.

Pathmanathan Pras P   Gray Richard A RA  

BioMed research international 20151026


The mechanisms underlying ventricular fibrillation (VF) are not well understood. The electrical activity on the heart surface during VF has been recorded extensively in the experimental setting and in some cases clinically; however, corresponding transmural activation patterns are prohibitively difficult to measure. In this paper, we use a high-resolution biventricular heart model to study three-dimensional electrical activity during fibrillation, focusing on the driving sources of VF: "filament  ...[more]

Similar Datasets

| S-EPMC6536150 | biostudies-literature
| S-EPMC7264405 | biostudies-literature
| S-EPMC4919062 | biostudies-literature
| S-EPMC5955749 | biostudies-literature
| S-EPMC3826179 | biostudies-literature
| S-EPMC3996562 | biostudies-literature
| S-EPMC4399506 | biostudies-other
| S-EPMC4974931 | biostudies-literature
| S-EPMC4405355 | biostudies-literature
| S-EPMC2993199 | biostudies-literature