A Novel Fixation Method for Variable-Sized Endoscopic Submucosal Dissection Specimens: An In Vitro Animal Experiment.


ABSTRACT:

Background

Endoscopic submucosal dissection is considered a curative and minimally invasive treatment for early gastric cancer; however, precise pathologic assessment of resected specimens is required to develop further treatment plans. Human error during specimen handling can affect objective assessment of resected specimens. In this study, we investigated whether a novel tissue fixation device offered more objective and standardized pathologic evaluation than conventional manual tissue fixation.

Methods

We developed a novel tissue fixation device for endoscopic submucosal dissection specimens. Two circular tissue samples 2, 3, and 4 cm in diameter were obtained from the body of 45 porcine stomachs. One specimen sample was placed in a fixation device; the other was manually fixed on corkboard. We used a pressure indicator to ensure constant pressure in the resected specimens in the fixation device. We measured submucosal diameter and thickness after 24 hr.

Results

The diameters for 2, 3, and 4 cm resected tissue samples were 23.85, 32.30, and 45.0 mm and 21.0, 32.0, and 44.50 mm for the fixation device and manual pinning groups, respectively. The submucosal thicknesses in the fixation device group were 397.09, 381.43, and 415.51 ?m and 393.76, 529.69, and 603.82 ?m by manual pinning for 2, 3, and 4 cm tissue samples, respectively. Analysis of standard deviation revealed that the submucosal thickness in the manual fixation group was much more variable than in the fixation device group (p = 0.012, 0.042, and 0.001 for 2, 3, and 4 cm tissue specimens, respectively; Fligner-Killeen test of homogeneity of variances).

Conclusions

Among variously sized resected tissue specimens, submucosal thicknesses were more variable in the conventional fixation group, while the thicknesses were comparatively consistent in the fixation device group. After endoscopic submucosal dissection, pathologic preparation using this fixation device could offer more objective assessment of specimens.

SUBMITTER: Kim SH 

PROVIDER: S-EPMC4704733 | biostudies-literature | 2016

REPOSITORIES: biostudies-literature

altmetric image

Publications

A Novel Fixation Method for Variable-Sized Endoscopic Submucosal Dissection Specimens: An In Vitro Animal Experiment.

Kim Seung Han SH   Choi Hyuk Soon HS   Chun Hoon Jai HJ   Yoo In Kyung IK   Lee Jae Min JM   Kim Eun Sun ES   Keum Bora B   Seo Yeon Seok YS   Jeen Yoon Tae YT   Lee Hong Sik HS   Um Soon Ho SH   Kim Chang Duck CD  

PloS one 20160107 1


<h4>Background</h4>Endoscopic submucosal dissection is considered a curative and minimally invasive treatment for early gastric cancer; however, precise pathologic assessment of resected specimens is required to develop further treatment plans. Human error during specimen handling can affect objective assessment of resected specimens. In this study, we investigated whether a novel tissue fixation device offered more objective and standardized pathologic evaluation than conventional manual tissue  ...[more]

Similar Datasets

| S-EPMC9347180 | biostudies-literature
| S-EPMC10099846 | biostudies-literature
| S-EPMC10794121 | biostudies-literature
| S-EPMC6317950 | biostudies-literature
| S-EPMC7221288 | biostudies-literature
| S-EPMC5989134 | biostudies-literature
| S-EPMC5773587 | biostudies-literature
| S-EPMC7004922 | biostudies-literature
| S-EPMC8828227 | biostudies-literature
| S-EPMC4260103 | biostudies-literature