Unknown

Dataset Information

0

Predicting Peri-Device Leakage of Left Atrial Appendage Device Closure Using Novel Three-Dimensional Geometric CT Analysis.


ABSTRACT:

Background

After left atrial appendage (LAA) device closure, peri-device leakage into the LAA persists due to incomplete occlusion. We hypothesized that pre-procedural three-dimensional (3D) geometric analysis of the interatrial septum (IAS) and LAA orifice can predict this leakage. We investigated the predictive parameters of LAA device closure obtained from baseline cardiac computerized tomography (CT) using a novel 3D analysis system.

Methods

We conducted a retrospective study of 22 patients who underwent LAA device closure. We defined peri-device leakage as the presence of a Doppler signal inside the LAA after device deployment (group 2, n = 5) compared with patients without peri-device leakage (group 1, n = 17). Conventional parameters were measured by cardiac CT. Angles ? and ? were defined between the IAS plane and the line, linking the LAA orifice center and foramen ovale.

Results

Group 2 exhibited significantly better left atrial (LA) function than group 1 (p = 0.031). Pre-procedural ? was also larger in this group (41.9° vs. 52.3°, p = 0.019). The LAA cauliflower-type morphology was more common in group 2. Overall, the patients' LA reserve significantly decreased after the procedure (21.7 mm(3) vs. 17.8 mm(3), p = 0.035). However, we observed no significant interval changes in pre- and post-procedural values of ? and ? in either group (all p > 0.05).

Conclusion

Angles between the IAS and LAA orifice might be a novel anatomical parameter for predicting peri-device leakage after LAA device closure. In addition, 3D CT analysis of the LA and LAA orifice could be used to identify clinically favorable candidates for LAA device closure.

SUBMITTER: Chung H 

PROVIDER: S-EPMC4707306 | biostudies-literature | 2015 Dec

REPOSITORIES: biostudies-literature

altmetric image

Publications

Predicting Peri-Device Leakage of Left Atrial Appendage Device Closure Using Novel Three-Dimensional Geometric CT Analysis.

Chung Hyemoon H   Jeon Byunghwan B   Chang Hyuk-Jae HJ   Han Dongjin D   Shim Hackjoon H   Cho In Jeong IJ   Shim Chi Young CY   Hong Geu-Ru GR   Kim Jung-Sun JS   Jang Yangsoo Y   Chung Namsik N  

Journal of cardiovascular ultrasound 20151230 4


<h4>Background</h4>After left atrial appendage (LAA) device closure, peri-device leakage into the LAA persists due to incomplete occlusion. We hypothesized that pre-procedural three-dimensional (3D) geometric analysis of the interatrial septum (IAS) and LAA orifice can predict this leakage. We investigated the predictive parameters of LAA device closure obtained from baseline cardiac computerized tomography (CT) using a novel 3D analysis system.<h4>Methods</h4>We conducted a retrospective study  ...[more]

Similar Datasets

| S-EPMC9856255 | biostudies-literature
| S-EPMC8877112 | biostudies-literature
| S-EPMC9434646 | biostudies-literature
| S-EPMC9729287 | biostudies-literature
| S-EPMC8311156 | biostudies-literature
| S-EPMC7891241 | biostudies-literature
| S-EPMC9352115 | biostudies-literature
| S-EPMC8183657 | biostudies-literature
| S-EPMC10307589 | biostudies-literature
| S-EPMC10956221 | biostudies-literature