Bright Lu2 O3 :Eu Thin-Film Scintillators for High-Resolution Radioluminescence Microscopy.


ABSTRACT: The performance of a new thin-film Lu2 O3 :Eu scintillator for single-cell radionuclide imaging is investigated. Imaging the metabolic properties of heterogeneous cell populations in real time is an important challenge with clinical implications. An innovative technique called radioluminescence microscopy has been developed to quantitatively and sensitively measure radionuclide uptake in single cells. The most important component of this technique is the scintillator, which converts the energy released during radioactive decay into luminescent signals. The sensitivity and spatial resolution of the imaging system depend critically on the characteristics of the scintillator, that is, the material used and its geometrical configuration. Scintillators fabricated using conventional methods are relatively thick and therefore do not provide optimal spatial resolution. A thin-film Lu2 O3 :Eu scintillator is compared to a conventional 500 ?m thick CdWO4 scintillator for radioluminescence imaging. Despite its thinness, the unique scintillation properties of the Lu2 O3 :Eu scintillator allow us to capture single-positron decays with fourfold higher sensitivity, which is a significant achievement. The thin-film Lu2 O3 :Eu scintillators also yield radioluminescence images where individual cells appear smaller and better resolved on average than with the CdWO4 scintillators. Coupled with the thin-film scintillator technology, radioluminescence microscopy can yield valuable and clinically relevant data on the metabolism of single cells.

SUBMITTER: Sengupta D 

PROVIDER: S-EPMC4715786 | biostudies-literature | 2015 Oct

REPOSITORIES: biostudies-literature

altmetric image

Publications

Bright Lu<sub>2</sub> O<sub>3</sub> :Eu Thin-Film Scintillators for High-Resolution Radioluminescence Microscopy.

Sengupta Debanti D   Miller Stuart S   Marton Zsolt Z   Chin Frederick F   Nagarkar Vivek V   Pratx Guillem G  

Advanced healthcare materials 20150716 14


The performance of a new thin-film Lu<sub>2</sub> O<sub>3</sub> :Eu scintillator for single-cell radionuclide imaging is investigated. Imaging the metabolic properties of heterogeneous cell populations in real time is an important challenge with clinical implications. An innovative technique called radioluminescence microscopy has been developed to quantitatively and sensitively measure radionuclide uptake in single cells. The most important component of this technique is the scintillator, which  ...[more]

Similar Datasets

| S-EPMC5496580 | biostudies-literature
| S-EPMC7559253 | biostudies-literature
| S-EPMC6959352 | biostudies-literature
| S-EPMC8656202 | biostudies-literature
| S-EPMC3211987 | biostudies-literature
| S-EPMC5839938 | biostudies-literature
| S-EPMC6972658 | biostudies-literature
| S-EPMC7265479 | biostudies-literature
| S-EPMC8777649 | biostudies-literature
| S-EPMC3522675 | biostudies-literature