Unknown

Dataset Information

0

In Vitro Longitudinal Relaxivity Profile of Gd(ABE-DTTA), an Investigational Magnetic Resonance Imaging Contrast Agent.


ABSTRACT:

Purpose

MRI contrast agents (CA) whose contrast enhancement remains relatively high even at the higher end of the magnetic field strength range would be desirable. The purpose of this work was to demonstrate such a desired magnetic field dependency of the longitudinal relaxivity for an experimental MRI CA, Gd(ABE-DTTA).

Materials and methods

The relaxivity of 0.5mM and 1mM Gd(ABE-DTTA) was measured by Nuclear Magnetic Relaxation Dispersion (NMRD) in the range of 0.0002 to 1T. Two MRI and five NMR instruments were used to cover the range between 1.5 to 20T. Parallel measurement of a Gd-DTPA sample was performed throughout as reference. All measurements were carried out at 37°C and pH 7.4.

Results

The relaxivity values of 0.5mM and 1mM Gd(ABE-DTTA) measured at 1.5, 3, and 7T, within the presently clinically relevant magnetic field range, were 15.3, 11.8, 12.4 s-1mM-1 and 18.1, 16.7, and 13.5 s-1mM-1, respectively. The control 4 mM Gd-DTPA relaxivities at the same magnetic fields were 3.6, 3.3, and 3.0 s-1mM-1, respectively.

Conclusions

The longitudinal relaxivity of Gd(ABE-DTTA) measured within the presently clinically relevant field range is three to five times higher than that of most commercially available agents. Thus, Gd(ABE-DTTA) could be a practical choice at any field strength currently used in clinical imaging including those at the higher end.

SUBMITTER: Varga-Szemes A 

PROVIDER: S-EPMC4752229 | biostudies-literature | 2016

REPOSITORIES: biostudies-literature

altmetric image

Publications

In Vitro Longitudinal Relaxivity Profile of Gd(ABE-DTTA), an Investigational Magnetic Resonance Imaging Contrast Agent.

Varga-Szemes Akos A   Kiss Pal P   Rab Andras A   Suranyi Pal P   Lenkey Zsofia Z   Simor Tamas T   Bryant Robert G RG   Elgavish Gabriel A GA  

PloS one 20160212 2


<h4>Purpose</h4>MRI contrast agents (CA) whose contrast enhancement remains relatively high even at the higher end of the magnetic field strength range would be desirable. The purpose of this work was to demonstrate such a desired magnetic field dependency of the longitudinal relaxivity for an experimental MRI CA, Gd(ABE-DTTA).<h4>Materials and methods</h4>The relaxivity of 0.5mM and 1mM Gd(ABE-DTTA) was measured by Nuclear Magnetic Relaxation Dispersion (NMRD) in the range of 0.0002 to 1T. Two  ...[more]

Similar Datasets

| S-EPMC2862651 | biostudies-literature
| S-EPMC4063760 | biostudies-literature
| S-EPMC5172589 | biostudies-literature
| S-EPMC3188310 | biostudies-literature
| S-EPMC2688742 | biostudies-literature
| S-EPMC6102570 | biostudies-literature
| S-EPMC3672249 | biostudies-other
| S-EPMC6939894 | biostudies-literature
| S-EPMC8162571 | biostudies-literature
| S-EPMC4841792 | biostudies-literature