Real-Time MRI-Guided Cardiac Cryo-Ablation: A Feasibility Study.


ABSTRACT: MRI-based ablation provides an attractive capability of seeing ablation-related tissue changes in real time. Here we describe a real-time MRI-based cardiac cryo-ablation system.Studies were performed in canine model (n = 4) using MR-compatible cryo-ablation devices built for animal use: focal cryo-catheter with 8 mm tip and 28 mm diameter cryo-balloon. The main steps of MRI-guided cardiac cryo-ablation procedure (real-time navigation, confirmation of tip-tissue contact, confirmation of vessel occlusion, real-time monitoring of a freeze zone formation, and intra-procedural assessment of lesions) were validated in a 3 Tesla clinical MRI scanner.The MRI compatible cryo-devices were advanced to the right atrium (RA) and right ventricle (RV) and their position was confirmed by real-time MRI. Specifically, contact between catheter tip and myocardium and occlusion of superior vena cava (SVC) by the balloon was visually validated. Focal cryo-lesions were created in the RV septum. Circumferential ablation of SVC-RA junction with no gaps was achieved using the cryo-balloon. Real-time visualization of freeze zone formation was achieved in all studies when lesions were successfully created. The ablations and presence of collateral damage were confirmed by T1-weighted and late gadolinium enhancement MRI and gross pathological examination.This study confirms the feasibility of a MRI-based cryo-ablation system in performing cardiac ablation procedures. The system allows real-time catheter navigation, confirmation of catheter tip-tissue contact, validation of vessel occlusion by cryo-balloon, real-time monitoring of a freeze zone formation, and intra-procedural assessment of ablations including collateral damage.

SUBMITTER: Kholmovski EG 

PROVIDER: S-EPMC4865432 | biostudies-literature | 2016 May

REPOSITORIES: biostudies-literature

altmetric image

Publications

Real-Time MRI-Guided Cardiac Cryo-Ablation: A Feasibility Study.

Kholmovski Eugene G EG   Coulombe Nicolas N   Silvernagel Joshua J   Angel Nathan N   Parker Dennis D   Macleod Rob R   Marrouche Nassir N   Ranjan Ravi R  

Journal of cardiovascular electrophysiology 20160321 5


<h4>Introduction</h4>MRI-based ablation provides an attractive capability of seeing ablation-related tissue changes in real time. Here we describe a real-time MRI-based cardiac cryo-ablation system.<h4>Methods</h4>Studies were performed in canine model (n = 4) using MR-compatible cryo-ablation devices built for animal use: focal cryo-catheter with 8 mm tip and 28 mm diameter cryo-balloon. The main steps of MRI-guided cardiac cryo-ablation procedure (real-time navigation, confirmation of tip-tiss  ...[more]

Similar Datasets

| S-EPMC3409423 | biostudies-literature
| S-EPMC4523869 | biostudies-other
| S-EPMC1463249 | biostudies-literature
| S-EPMC3561614 | biostudies-literature
| S-EPMC7560864 | biostudies-literature
| S-EPMC7701108 | biostudies-literature
| S-EPMC8140156 | biostudies-literature
| S-EPMC6778713 | biostudies-literature
| S-EPMC4551954 | biostudies-literature