Comparison of Serum Spec fPL(™) and 1,2-o-Dilauryl-Rac-Glycero-3-Glutaric Acid-(6'-Methylresorufin) Ester Assay in 60 Cats Using Standardized Assessment of Pancreatic Histology.


ABSTRACT:

Background

Feline pancreas-specific lipase (Spec fPL) is considered a useful test for the antemortem diagnosis of pancreatitis in cats. A recent study found good agreement between the results of the Spec fPL and catalytic 1,2-o-dilauryl-rac-glycero-3-glutaric acid-(6'-methylresorufin) ester (DGGR) lipase assay. Prospective studies evaluating their sensitivity and specificity are lacking.

Objectives

To compare the results of the Spec fPL and the DGGR assays with a standardized histologic assessment of the pancreas.

Animals

Sixty client-owned cats presented for necropsy.

Methods

Prospective study

Spec fPL concentrations and serum DGGR lipase activity were measured from the same blood sample. The pancreas was removed within 3 hours after euthanasia; serial transverse sections were made every 0.5 cm throughout the entire pancreas and reviewed using a histologic grading scheme. Sensitivity and specificity for the Spec fPL and DGGR assay results were determined.

Results

The sensitivity and specificity for the Spec fPL assay (cutoff value ?5.4 ?g/L) was 42.1 [95% confidence interval (95% CI), 29.4-55.9%] and 100% (95% CI, 31.0-100.0%). The sensitivity and specificity for the DGGR assay (cutoff value >26 U/L) was 36.8 (95% CI, 24.7-50.7%) and 100% (95% CI, 31.0-100.0%). When lymphocytic inflammation up to 10% of a section was considered normal, the sensitivity and specificity for Spec fPL assay (cutoff value ?5.4 ?g/L) was 61.1 (95% CI, 36.1-81.7%) and 69.0% (95% CI, 52.8-81.9%) and the sensitivity and specificity for the DGGR assay (cutoff value >26 U/L) was 66.7 (95% CI, 41.2-85.6%) and 78.6% (95% CI, 62.8-89.2%).

Conclusions and clinical importance

Both lipase assays performed similarly well, but their agreement with histologic pancreatic inflammation was limited.

SUBMITTER: Oppliger S 

PROVIDER: S-EPMC4913568 | biostudies-literature | 2016 May

REPOSITORIES: biostudies-literature

altmetric image

Publications

Comparison of Serum Spec fPL(™) and 1,2-o-Dilauryl-Rac-Glycero-3-Glutaric Acid-(6'-Methylresorufin) Ester Assay in 60 Cats Using Standardized Assessment of Pancreatic Histology.

Oppliger S S   Hilbe M M   Hartnack S S   Zini E E   Reusch C E CE   Kook P H PH  

Journal of veterinary internal medicine 20160310 3


<h4>Background</h4>Feline pancreas-specific lipase (Spec fPL) is considered a useful test for the antemortem diagnosis of pancreatitis in cats. A recent study found good agreement between the results of the Spec fPL and catalytic 1,2-o-dilauryl-rac-glycero-3-glutaric acid-(6'-methylresorufin) ester (DGGR) lipase assay. Prospective studies evaluating their sensitivity and specificity are lacking.<h4>Objectives</h4>To compare the results of the Spec fPL and the DGGR assays with a standardized hist  ...[more]

Similar Datasets

| S-EPMC10061187 | biostudies-literature
| S-EPMC4667670 | biostudies-literature
| S-EPMC3025725 | biostudies-literature
| S-EPMC7096630 | biostudies-literature
| S-EPMC1223697 | biostudies-other
| S-EPMC10800178 | biostudies-literature
| S-EPMC6796685 | biostudies-literature
| S-EPMC2556991 | biostudies-literature
| S-EPMC4391204 | biostudies-literature
| S-EPMC6043949 | biostudies-literature