Unknown

Dataset Information

0

Correlation of primary middle and distal esophageal cancers motion with surrounding tissues using four-dimensional computed tomography.


ABSTRACT: PURPOSE:To investigate the correlation of gross tumor volume (GTV) motion with the structure of interest (SOI) motion and volume variation for middle and distal esophageal cancers using four-dimensional computed tomography (4DCT). PATIENTS AND METHODS:Thirty-three patients with middle or distal esophageal carcinoma underwent 4DCT simulation scan during free breathing. All image sets were registered with 0% phase, and the GTV, apex of diaphragm, lung, and heart were delineated on each phase of the 4DCT data. The position of GTV and SOI was identified in all 4DCT phases, and the volume of lung and heart was also achieved. The phase relationship between the GTV and SOI was estimated through Pearson's correlation test. RESULTS:The mean peak-to-peak displacement of all primary tumors in the lateral (LR), anteroposterior (AP), and superoinferior (SI) directions was 0.13 cm, 0.20 cm, and 0.30 cm, respectively. The SI peak-to-peak motion of the GTV was defined as the greatest magnitude of motion. The displacement of GTV correlated well with heart in three dimensions and significantly associated with bilateral lung in LR and SI directions. A significant correlation was found between the GTV and apex of the diaphragm in SI direction (r left=0.918 and r right=0.928). A significant inverse correlation was found between GTV motion and varying lung volume, but the correlation was not significant with heart (r LR=-0.530, r AP=-0.531, and r SI=-0.588) during respiratory cycle. CONCLUSION:For middle and distal esophageal cancers, GTV should expand asymmetric internal margins. The primary tumor motion has quite good correlation with diaphragm, heart, and lung.

SUBMITTER: Wang W 

PROVIDER: S-EPMC4922815 | biostudies-literature | 2016

REPOSITORIES: biostudies-literature

altmetric image

Publications

Correlation of primary middle and distal esophageal cancers motion with surrounding tissues using four-dimensional computed tomography.

Wang Wei W   Li Jianbin J   Zhang Yingjie Y   Shao Qian Q   Xu Min M   Guo Bing B   Shang Dongping D  

OncoTargets and therapy 20160622


<h4>Purpose</h4>To investigate the correlation of gross tumor volume (GTV) motion with the structure of interest (SOI) motion and volume variation for middle and distal esophageal cancers using four-dimensional computed tomography (4DCT).<h4>Patients and methods</h4>Thirty-three patients with middle or distal esophageal carcinoma underwent 4DCT simulation scan during free breathing. All image sets were registered with 0% phase, and the GTV, apex of diaphragm, lung, and heart were delineated on e  ...[more]

Similar Datasets

| S-EPMC8792087 | biostudies-literature
| S-EPMC10278033 | biostudies-literature
| S-EPMC9200445 | biostudies-literature
| S-EPMC9742185 | biostudies-literature
| S-EPMC5639881 | biostudies-literature
| S-EPMC3829388 | biostudies-literature
| S-EPMC3979277 | biostudies-literature
| S-EPMC3395474 | biostudies-literature
| S-EPMC7729323 | biostudies-literature
| S-EPMC7277134 | biostudies-literature