Towards high-resolution 4D flow MRI in the human aorta using kt-GRAPPA and B1+ shimming at 7T.


ABSTRACT:

Purpose

To evaluate the feasibility of aortic 4D flow magnetic resonance imaging (MRI) at 7T with improved spatial resolution using kt-GRAPPA acceleration while restricting acquisition time and to address radiofrequency (RF) excitation heterogeneities with B1+ shimming.

Materials and methods

4D flow MRI data were obtained in the aorta of eight subjects using a 16-channel transmit/receive coil array at 7T. Flow quantification and acquisition time were compared for a kt-GRAPPA accelerated (R = 5) and a standard GRAPPA (R = 2) accelerated protocol. The impact of different dynamic B1+ shimming strategies on flow quantification was investigated. Two kt-GRAPPA accelerated protocols with 1.2 × 1.2 × 1.2 mm(3) and 1.8 × 1.8 × 2.4 mm(3) spatial resolution were compared.

Results

Using kt-GRAPPA, we achieved a 4.3-fold reduction in net acquisition time resulting in scan times of about 10 minutes. No significant effect on flow quantification was observed compared to standard GRAPPA with R = 2. Optimizing the B1+ fields for the aorta impacted significantly (P <  0.05) the flow quantification while specific B1+ settings were required for respiration navigators. The high-resolution protocol yielded similar flow quantification, but allowed the depiction of branching vessels.

Conclusion

7T in combination with B1+ shimming allows for high-resolution 4D flow MRI acquisitions in the human aorta, while kt-GRAPPA limits total scan times without affecting flow quantification. J. Magn. Reson. Imaging 2016;44:486-499.

SUBMITTER: Schmitter S 

PROVIDER: S-EPMC4947022 | biostudies-literature | 2016 Aug

REPOSITORIES: biostudies-literature

altmetric image

Publications

Towards high-resolution 4D flow MRI in the human aorta using kt-GRAPPA and B1+ shimming at 7T.

Schmitter Sebastian S   Schnell Susanne S   Uğurbil Kâmil K   Markl Michael M   Van de Moortele Pierre-François PF  

Journal of magnetic resonance imaging : JMRI 20160203 2


<h4>Purpose</h4>To evaluate the feasibility of aortic 4D flow magnetic resonance imaging (MRI) at 7T with improved spatial resolution using kt-GRAPPA acceleration while restricting acquisition time and to address radiofrequency (RF) excitation heterogeneities with B1+ shimming.<h4>Materials and methods</h4>4D flow MRI data were obtained in the aorta of eight subjects using a 16-channel transmit/receive coil array at 7T. Flow quantification and acquisition time were compared for a kt-GRAPPA accel  ...[more]

Similar Datasets

| S-EPMC11398588 | biostudies-literature
| S-EPMC9910837 | biostudies-literature
| S-EPMC8616784 | biostudies-literature
| S-EPMC7652092 | biostudies-literature
| S-EPMC7984392 | biostudies-literature
| S-EPMC9804839 | biostudies-literature
| S-EPMC10962593 | biostudies-literature
| S-EPMC9845193 | biostudies-literature
| S-EPMC10945835 | biostudies-literature
| S-EPMC6294732 | biostudies-literature