The Fast and Easy Way for Double-Lumen Tube Intubation: Individual Angle-Modification.


ABSTRACT: To find the faster and easier way than the existing intubating technique for double-lumen tube, we modified the angle of double-lumen tube according to an individual's upper airway anatomy and compared the time needed and the number of attempts for successful intubation between individually angle-modified and non-modified double-lumen tubes. Adult patients undergoing elective thoracic surgery were randomly allocated in either non-angle-modified (Group N, n = 54) or angle-modified (Group M, n = 54) groups. During mask ventilation in the sniffing position, angle-modification was performed in Group M as follows: the distal tip of the tube was placed at the level of the cricoid cartilage and the shaft was bent at the intersection of the oral and pharyngeal axes estimated from the patient's surface anatomy. The time needed and the number of attempts for successful intubation and Cormack and Lehane (C-L) grade were recorded. Overall median intubation time (sec) was significantly shorter in Group M than in Group N [10.2 vs. 15.1, P<0.001]. In addition, Group M showed the shorter median intubation time (sec) in C-L grades I-III [8.2 vs. 11.1 in C-L grade I, (P = 0.003), 10.3 vs. 15.3 in II, (P = 0.001), and 11.8 vs. 27.9 in III, (P<0.001), respectively]. Moreover, all intubation was successfully performed at the first attempt in patients with C-L grades I-III in Group M (P = 0.027). Our study showed an individual angle-modification would be useful for the fast and easy intubation of double-lumen tube in patients with C-L grades I-III.ClinicalTrials.gov NCT02190032.

SUBMITTER: Min JJ 

PROVIDER: S-EPMC4990269 | biostudies-literature | 2016

REPOSITORIES: biostudies-literature

altmetric image

Publications

The Fast and Easy Way for Double-Lumen Tube Intubation: Individual Angle-Modification.

Min Jeong Jin JJ   Lee Jong-Hwan JH   Kang Se Hee SH   Kim Eunhee E   Lee Sangmin M SM   Cho Jong Ho JH   Kim Hong Kwan HK  

PloS one 20160818 8


<h4>Unlabelled</h4>To find the faster and easier way than the existing intubating technique for double-lumen tube, we modified the angle of double-lumen tube according to an individual's upper airway anatomy and compared the time needed and the number of attempts for successful intubation between individually angle-modified and non-modified double-lumen tubes. Adult patients undergoing elective thoracic surgery were randomly allocated in either non-angle-modified (Group N, n = 54) or angle-modif  ...[more]

Similar Datasets

| S-EPMC5181831 | biostudies-literature
| S-EPMC6136707 | biostudies-literature
| S-EPMC4158352 | biostudies-literature
| S-EPMC7643342 | biostudies-literature
| S-EPMC7455027 | biostudies-literature
| S-EPMC8566095 | biostudies-literature
| S-EPMC3745901 | biostudies-literature
| S-EPMC8658072 | biostudies-literature
| S-EPMC8659221 | biostudies-literature
| S-EPMC6334414 | biostudies-literature