ABSTRACT: Background
Diagnosing atrial fibrillation (AF) before ischemic stroke occurs is a priority for stroke prevention in AF. Smartphone camera-based photoplethysmographic (PPG) pulse waveform measurement discriminates between different heart rhythms, but its ability to diagnose AF in real-world situations has not been adequately investigated. We sought to assess the diagnostic performance of a standalone smartphone PPG application, Cardiio Rhythm, for AF screening in primary care setting.Methods and results
Patients with hypertension, with diabetes mellitus, and/or aged ?65 years were recruited. A single-lead ECG was recorded by using the AliveCor heart monitor with tracings reviewed subsequently by 2 cardiologists to provide the reference standard. PPG measurements were performed by using the Cardiio Rhythm smartphone application. AF was diagnosed in 28 (2.76%) of 1013 participants. The diagnostic sensitivity of the Cardiio Rhythm for AF detection was 92.9% (95% CI] 77-99%) and was higher than that of the AliveCor automated algorithm (71.4% [95% CI 51-87%]). The specificities of Cardiio Rhythm and the AliveCor automated algorithm were comparable (97.7% [95% CI: 97-99%] versus 99.4% [95% CI 99-100%]). The positive predictive value of the Cardiio Rhythm was lower than that of the AliveCor automated algorithm (53.1% [95% CI 38-67%] versus 76.9% [95% CI 56-91%]); both had a very high negative predictive value (99.8% [95% CI 99-100%] versus 99.2% [95% CI 98-100%]).Conclusions
The Cardiio Rhythm smartphone PPG application provides an accurate and reliable means to detect AF in patients at risk of developing AF and has the potential to enable population-based screening for AF.
SUBMITTER: Chan PH
PROVIDER: S-EPMC5015379 | biostudies-literature | 2016 Jul
REPOSITORIES: biostudies-literature
Chan Pak-Hei PH Wong Chun-Ka CK Poh Yukkee C YC Pun Louise L Leung Wangie Wan-Chiu WW Wong Yu-Fai YF Wong Michelle Man-Ying MM Poh Ming-Zher MZ Chu Daniel Wai-Sing DW Siu Chung-Wah CW
Journal of the American Heart Association 20160721 7
<h4>Background</h4>Diagnosing atrial fibrillation (AF) before ischemic stroke occurs is a priority for stroke prevention in AF. Smartphone camera-based photoplethysmographic (PPG) pulse waveform measurement discriminates between different heart rhythms, but its ability to diagnose AF in real-world situations has not been adequately investigated. We sought to assess the diagnostic performance of a standalone smartphone PPG application, Cardiio Rhythm, for AF screening in primary care setting.<h4> ...[more]