Unknown

Dataset Information

0

Validity and Reliability of Ventilatory and Blood Lactate Thresholds in Well-Trained Cyclists.


ABSTRACT:

Purpose

The purpose of this study was to determine, i) the reliability of blood lactate and ventilatory-based thresholds, ii) the lactate threshold that corresponds with each ventilatory threshold (VT1 and VT2) and with maximal lactate steady state test (MLSS) as a proxy of cycling performance.

Methods

Fourteen aerobically-trained male cyclists ([Formula: see text] 62.1±4.6 ml·kg-1·min-1) performed two graded exercise tests (50 W warm-up followed by 25 W·min-1) to exhaustion. Blood lactate, [Formula: see text] and [Formula: see text] data were collected at every stage. Workloads at VT1 (rise in [Formula: see text];) and VT2 (rise in [Formula: see text]) were compared with workloads at lactate thresholds. Several continuous tests were needed to detect the MLSS workload. Agreement and differences among tests were assessed with ANOVA, ICC and Bland-Altman. Reliability of each test was evaluated using ICC, CV and Bland-Altman plots.

Results

Workloads at lactate threshold (LT) and LT+2.0 mMol·L-1 matched the ones for VT1 and VT2, respectively (p = 0.147 and 0.539; r = 0.72 and 0.80; Bias = -13.6 and 2.8, respectively). Furthermore, workload at LT+0.5 mMol·L-1 coincided with MLSS workload (p = 0.449; r = 0.78; Bias = -4.5). Lactate threshold tests had high reliability (CV = 3.4-3.7%; r = 0.85-0.89; Bias = -2.1-3.0) except for DMAX method (CV = 10.3%; r = 0.57; Bias = 15.4). Ventilatory thresholds show high reliability (CV = 1.6%-3.5%; r = 0.90-0.96; Bias = -1.8-2.9) except for RER = 1 and V-Slope (CV = 5.0-6.4%; r = 0.79; Bias = -5.6-12.4).

Conclusions

Lactate threshold tests can be a valid and reliable alternative to ventilatory thresholds to identify the workloads at the transition from aerobic to anaerobic metabolism.

SUBMITTER: Pallares JG 

PROVIDER: S-EPMC5033582 | biostudies-literature | 2016

REPOSITORIES: biostudies-literature

altmetric image

Publications

Validity and Reliability of Ventilatory and Blood Lactate Thresholds in Well-Trained Cyclists.

Pallarés Jesús G JG   Morán-Navarro Ricardo R   Ortega Juan Fernando JF   Fernández-Elías Valentín Emilio VE   Mora-Rodriguez Ricardo R  

PloS one 20160922 9


<h4>Purpose</h4>The purpose of this study was to determine, i) the reliability of blood lactate and ventilatory-based thresholds, ii) the lactate threshold that corresponds with each ventilatory threshold (VT1 and VT2) and with maximal lactate steady state test (MLSS) as a proxy of cycling performance.<h4>Methods</h4>Fourteen aerobically-trained male cyclists ([Formula: see text] 62.1±4.6 ml·kg-1·min-1) performed two graded exercise tests (50 W warm-up followed by 25 W·min-1) to exhaustion. Bloo  ...[more]

Similar Datasets

| S-EPMC7546976 | biostudies-literature
| S-EPMC7580004 | biostudies-literature
| S-EPMC10963392 | biostudies-literature
| S-EPMC3586176 | biostudies-literature
| S-EPMC3787919 | biostudies-other
| S-EPMC2905840 | biostudies-literature
| S-EPMC6209185 | biostudies-literature
| S-EPMC7390385 | biostudies-literature
| S-EPMC10191994 | biostudies-literature
| S-EPMC7545350 | biostudies-literature