Unknown

Dataset Information

0

Electrophysiological Determination of Submembrane Na(+) Concentration in Cardiac Myocytes.


ABSTRACT: In the heart, Na(+) is a key modulator of the action potential, Ca(2+) homeostasis, energetics, and contractility. Because Na(+) currents and cotransport fluxes depend on the Na(+) concentration in the submembrane region, it is necessary to accurately estimate the submembrane Na(+) concentration ([Na(+)]sm). Current methods using Na(+)-sensitive fluorescent indicators or Na(+) -sensitive electrodes cannot measure [Na(+)]sm. However, electrophysiology methods are ideal for measuring [Na(+)]sm. In this article, we develop patch-clamp protocols and experimental conditions to determine the upper bound of [Na(+)]sm at the peak of action potential and its lower bound at the resting state. During the cardiac cycle, the value of [Na(+)]sm is constrained within these bounds. We conducted experiments in rabbit ventricular myocytes at body temperature and found that 1) at a low pacing frequency of 0.5 Hz, the upper and lower bounds converge at 9 mM, constraining the [Na(+)]sm value to ?9 mM; 2) at 2 Hz pacing frequency, [Na(+)]sm is bounded between 9 mM at resting state and 11.5 mM; and 3) the cells can maintain [Na(+)]sm to the above values, despite changes in the pipette Na(+) concentration, showing autoregulation of Na(+) in beating cardiomyocytes.

SUBMITTER: Hegyi B 

PROVIDER: S-EPMC5034366 | biostudies-literature | 2016 Sep

REPOSITORIES: biostudies-literature

altmetric image

Publications

Electrophysiological Determination of Submembrane Na(+) Concentration in Cardiac Myocytes.

Hegyi Bence B   Bányász Tamás T   Shannon Thomas R TR   Chen-Izu Ye Y   Izu Leighton T LT  

Biophysical journal 20160901 6


In the heart, Na(+) is a key modulator of the action potential, Ca(2+) homeostasis, energetics, and contractility. Because Na(+) currents and cotransport fluxes depend on the Na(+) concentration in the submembrane region, it is necessary to accurately estimate the submembrane Na(+) concentration ([Na(+)]sm). Current methods using Na(+)-sensitive fluorescent indicators or Na(+) -sensitive electrodes cannot measure [Na(+)]sm. However, electrophysiology methods are ideal for measuring [Na(+)]sm. In  ...[more]

Similar Datasets

| S-EPMC3882478 | biostudies-literature
| S-EPMC1351072 | biostudies-literature
| S-EPMC5496509 | biostudies-literature
| S-EPMC2776256 | biostudies-literature
| S-EPMC2946079 | biostudies-literature
| S-EPMC9736168 | biostudies-literature
| S-EPMC2717350 | biostudies-literature
| S-EPMC5485997 | biostudies-literature
| S-EPMC6014982 | biostudies-literature
| S-EPMC2711867 | biostudies-literature