Unknown

Dataset Information

0

Selective detection of dopamine with an all PEDOT:PSS Organic Electrochemical Transistor.


ABSTRACT: An all PEDOT:PSS Organic Electrochemical Transistor (OECT) has been developed and used for the selective detection of dopamine (DA) in the presence of interfering compounds (ascorbic acid, AA and uric acid, UA). The selective response has been implemented using a potentiodynamic approach, by varying the operating gate voltage and the scan rate. The trans-conductance curves allow to obtain a linear calibration plot for AA, UA and DA and to separate the redox waves associated to each compound; for this purpose, the scan rate is an important parameter to achieve a good resolution. The sensitivities and limits of detection obtained with the OECT have been compared with those obtained by potential step amperometric techniques (cyclic voltammetry and differential pulse voltammetry), employing a PEDOT:PSS working electrode: our results prove that the all-PEDOT:PSS OECT sensitivities and limits of detection are comparable or even better than those obtained by DPV, a technique that employs a sophisticate potential wave and read-out system in order to maximize the performance of electrochemical sensors and that can hardly be considered a viable readout method in practical applications.

SUBMITTER: Gualandi I 

PROVIDER: S-EPMC5064404 | biostudies-literature | 2016 Oct

REPOSITORIES: biostudies-literature

altmetric image

Publications

Selective detection of dopamine with an all PEDOT:PSS Organic Electrochemical Transistor.

Gualandi Isacco I   Tonelli Domenica D   Mariani Federica F   Scavetta Erika E   Marzocchi Marco M   Fraboni Beatrice B  

Scientific reports 20161014


An all PEDOT:PSS Organic Electrochemical Transistor (OECT) has been developed and used for the selective detection of dopamine (DA) in the presence of interfering compounds (ascorbic acid, AA and uric acid, UA). The selective response has been implemented using a potentiodynamic approach, by varying the operating gate voltage and the scan rate. The trans-conductance curves allow to obtain a linear calibration plot for AA, UA and DA and to separate the redox waves associated to each compound; for  ...[more]

Similar Datasets

| S-EPMC10719902 | biostudies-literature
| S-EPMC9079364 | biostudies-literature
| S-EPMC7283208 | biostudies-literature
| S-EPMC6155079 | biostudies-other
| S-EPMC3919119 | biostudies-literature
| S-EPMC10535691 | biostudies-literature
| S-EPMC9855352 | biostudies-literature
| S-EPMC10958448 | biostudies-literature
| S-EPMC10747145 | biostudies-literature
| S-EPMC6337112 | biostudies-literature