Unknown

Dataset Information

0

Surface plasmon resonance microscopy: Achieving a quantitative optical response.


ABSTRACT: Surface plasmon resonance (SPR) imaging allows real-time label-free imaging based on index of refraction and changes in index of refraction at an interface. Optical parameter analysis is achieved by application of the Fresnel model to SPR data typically taken by an instrument in a prism based figuration. We carry out SPR imaging on a microscope by launching light into a sample and collecting reflected light through a high numerical aperture microscope objective. The SPR microscope enables spatial resolution that approaches the diffraction limit and has a dynamic range that allows detection of subnanometer to submicrometer changes in thickness of biological material at a surface. However, unambiguous quantitative interpretation of SPR changes using the microscope system could not be achieved using the Fresnel model because of polarization dependent attenuation and optical aberration that occurs in the high numerical aperture objective. To overcome this problem, we demonstrate a model to correct for polarization diattenuation and optical aberrations in the SPR data and develop a procedure to calibrate reflectivity to index of refraction values. The calibration and correction strategy for quantitative analysis was validated by comparing the known indices of refraction of bulk materials with corrected SPR data interpreted with the Fresnel model. Subsequently, we applied our SPR microscopy method to evaluate the index of refraction for a series of polymer microspheres in aqueous media and validated the quality of the measurement with quantitative phase microscopy.

SUBMITTER: Peterson AW 

PROVIDER: S-EPMC5116909 | biostudies-literature | 2016 Sep

REPOSITORIES: biostudies-literature

altmetric image

Publications

Surface plasmon resonance microscopy: Achieving a quantitative optical response.

Peterson Alexander W AW   Halter Michael M   Plant Anne L AL   Elliott John T JT  

The Review of scientific instruments 20160901 9


Surface plasmon resonance (SPR) imaging allows real-time label-free imaging based on index of refraction and changes in index of refraction at an interface. Optical parameter analysis is achieved by application of the Fresnel model to SPR data typically taken by an instrument in a prism based figuration. We carry out SPR imaging on a microscope by launching light into a sample and collecting reflected light through a high numerical aperture microscope objective. The SPR microscope enables spatia  ...[more]

Similar Datasets

| S-EPMC9617892 | biostudies-literature
| S-EPMC3660850 | biostudies-literature
| S-EPMC8674647 | biostudies-literature
| S-EPMC2669781 | biostudies-literature
| S-EPMC5098189 | biostudies-literature
| S-EPMC4735334 | biostudies-other
| S-EPMC5372468 | biostudies-literature
| S-EPMC3111218 | biostudies-literature
| S-EPMC6452698 | biostudies-literature
| S-EPMC5835214 | biostudies-literature