Engineered electrical conduction tract restores conduction in complete heart block: from in vitro to in vivo proof of concept.


ABSTRACT: Cardiac electrical conduction delays and blocks cause rhythm disturbances such as complete heart block, which can be fatal. Standard of care relies on electronic devices to artificially restore synchrony. We sought to create a new modality for treating these disorders by engineering electrical conduction tracts designed to propagate electrical impulses.This study sought to create a new approach for treating cardiac conduction disorders by using engineered electrical conduction tracts (EECTs).Paramagnetic beads were conjugated with an antibody to gamma-sarcoglycan, a cardiomyocyte cell surface antigen, and mixed with freshly isolated neonatal rat ventricular cardiomyocytes. A magnetic field was used to pattern a linear EECT.In an in vitro model of conduction block, the EECT was patterned so that it connected 2 independently beating neonatal rat ventricular cardiomyocyte monolayers; it achieved coordinated electrical activity, with action potentials propagating from 1 region to the other via EECT. Spiking the EECT with heart-derived stromal cells yielded stable structures with highly reproducible conduction velocities. Transplantation of EECTs in vivo restored atrioventricular conduction in a rat model of complete heart block.An EECT can re-establish electrical conduction in the heart. This novel approach could, in principle, be used not only to treat cardiac arrhythmias but also to repair other organs.

SUBMITTER: Cingolani E 

PROVIDER: S-EPMC5235386 | biostudies-literature | 2014 Dec

REPOSITORIES: biostudies-literature

altmetric image

Publications

Engineered electrical conduction tract restores conduction in complete heart block: from in vitro to in vivo proof of concept.

Cingolani Eugenio E   Ionta Vittoria V   Cheng Ke K   Giacomello Alessandro A   Cho Hee Cheol HC   Marbán Eduardo E  

Journal of the American College of Cardiology 20141201 24


<h4>Background</h4>Cardiac electrical conduction delays and blocks cause rhythm disturbances such as complete heart block, which can be fatal. Standard of care relies on electronic devices to artificially restore synchrony. We sought to create a new modality for treating these disorders by engineering electrical conduction tracts designed to propagate electrical impulses.<h4>Objectives</h4>This study sought to create a new approach for treating cardiac conduction disorders by using engineered el  ...[more]

Similar Datasets

| S-EPMC6726386 | biostudies-literature
| S-EPMC5474950 | biostudies-literature
| S-EPMC3340354 | biostudies-literature
| S-EPMC5345747 | biostudies-literature
| S-EPMC6534346 | biostudies-literature
| S-EPMC7402519 | biostudies-literature
| S-EPMC6628866 | biostudies-literature
| S-EPMC7390969 | biostudies-literature
| S-EPMC6426093 | biostudies-literature
| S-EPMC5505406 | biostudies-literature