Unknown

Dataset Information

0

Effect of Positive End-Expiratory Pressure on the Sonographic Optic Nerve Sheath Diameter as a Surrogate for Intracranial Pressure during Robot-Assisted Laparoscopic Prostatectomy: A Randomized Controlled Trial.


ABSTRACT: Positive end-expiratory pressure (PEEP) can increase intracranial pressure. Pneumoperitoneum and the Trendelenburg position are associated with an increased intracranial pressure. We investigated whether PEEP ventilation could additionally influence the sonographic optic nerve sheath diameter as a surrogate for intracranial pressure during pneumoperitoneum combined with the Trendelenburg position in patients undergoing robot-assisted laparoscopic prostatectomy.After anesthetic induction, 38 patients were randomly allocated to a low tidal volume ventilation (8 ml/kg) without PEEP group (zero end-expiratory pressure [ZEEP] group, n = 19) or low tidal volume ventilation with 8 cmH2O PEEP group (PEEP group, n = 19). The sonographic optic nerve sheath diameter was measured prior to skin incision, 5 min and 30 min after pneumoperitoneum and the Trendelenburg position, and at the end of surgery. The study endpoint was the difference in the sonographic optic nerve sheath diameter 5 min after pneumoperitoneum and the Trendelenburg position between the ZEEP and PEEP groups.Optic nerve sheath diameters 5 min after pneumoperitoneum and the Trendelenburg position did not significantly differ between the groups [least square mean (95% confidence interval); 4.8 (4.6-4.9) mm vs 4.8 (4.7-5.0) mm, P = 0.618]. Optic nerve sheath diameters 30 min after pneumoperitoneum and the Trendelenburg position also did not differ between the groups [least square mean (95% confidence interval); 4.5 (4.3-4.6) mm vs 4.5 (4.4-4.6) mm, P = 0.733].An 8 cmH2O PEEP application under low tidal volume ventilation does not induce an increase in the optic nerve sheath diameter during pneumoperitoneum combined with the steep Trendelenburg position, suggesting that there might be no detrimental effects of PEEP on the intracranial pressure during robot-assisted laparoscopic prostatectomy.ClinicalTrial.gov NCT02516566.

SUBMITTER: Chin JH 

PROVIDER: S-EPMC5249217 | biostudies-literature | 2017

REPOSITORIES: biostudies-literature

altmetric image

Publications

Effect of Positive End-Expiratory Pressure on the Sonographic Optic Nerve Sheath Diameter as a Surrogate for Intracranial Pressure during Robot-Assisted Laparoscopic Prostatectomy: A Randomized Controlled Trial.

Chin Ji-Hyun JH   Kim Wook-Jong WJ   Lee Joonho J   Han Yun A YA   Lim Jinwook J   Hwang Jai-Hyun JH   Cho Seong-Sik SS   Kim Young-Kug YK  

PloS one 20170120 1


<h4>Background</h4>Positive end-expiratory pressure (PEEP) can increase intracranial pressure. Pneumoperitoneum and the Trendelenburg position are associated with an increased intracranial pressure. We investigated whether PEEP ventilation could additionally influence the sonographic optic nerve sheath diameter as a surrogate for intracranial pressure during pneumoperitoneum combined with the Trendelenburg position in patients undergoing robot-assisted laparoscopic prostatectomy.<h4>Methods</h4>  ...[more]

Similar Datasets

| S-EPMC6455825 | biostudies-literature
| S-EPMC6011519 | biostudies-literature
| S-EPMC6831248 | biostudies-literature
| S-EPMC8342820 | biostudies-literature
| S-EPMC6203556 | biostudies-literature
| S-EPMC6999916 | biostudies-literature
| S-EPMC7080675 | biostudies-literature
| S-EPMC9652925 | biostudies-literature
| S-EPMC8027451 | biostudies-literature
| S-EPMC4324219 | biostudies-literature