Unknown

Dataset Information

0

Semi-automatic 10/20 Identification Method for MRI-Free Probe Placement in Transcranial Brain Mapping Techniques.


ABSTRACT: The International 10/20 system is an important head-surface-based positioning system for transcranial brain mapping techniques, e.g., fNIRS and TMS. As guidance for probe placement, the 10/20 system permits both proper ROI coverage and spatial consistency among multiple subjects and experiments in a MRI-free context. However, the traditional manual approach to the identification of 10/20 landmarks faces problems in reliability and time cost. In this study, we propose a semi-automatic method to address these problems. First, a novel head surface reconstruction algorithm reconstructs head geometry from a set of points uniformly and sparsely sampled on the subject's head. Second, virtual 10/20 landmarks are determined on the reconstructed head surface in computational space. Finally, a visually-guided real-time navigation system guides the experimenter to each of the identified 10/20 landmarks on the physical head of the subject. Compared with the traditional manual approach, our proposed method provides a significant improvement both in reliability and time cost and thus could contribute to improving both the effectiveness and efficiency of 10/20-guided MRI-free probe placement.

SUBMITTER: Xiao X 

PROVIDER: S-EPMC5269592 | biostudies-literature | 2017

REPOSITORIES: biostudies-literature

altmetric image

Publications

Semi-automatic 10/20 Identification Method for MRI-Free Probe Placement in Transcranial Brain Mapping Techniques.

Xiao Xiang X   Zhu Hao H   Liu Wei-Jie WJ   Yu Xiao-Ting XT   Duan Lian L   Li Zheng Z   Zhu Chao-Zhe CZ  

Frontiers in neuroscience 20170127


The International 10/20 system is an important head-surface-based positioning system for transcranial brain mapping techniques, e.g., fNIRS and TMS. As guidance for probe placement, the 10/20 system permits both proper ROI coverage and spatial consistency among multiple subjects and experiments in a MRI-free context. However, the traditional manual approach to the identification of 10/20 landmarks faces problems in reliability and time cost. In this study, we propose a semi-automatic method to a  ...[more]

Similar Datasets

| S-EPMC7157985 | biostudies-literature
| S-EPMC2654970 | biostudies-literature
| S-EPMC7914808 | biostudies-literature
| S-EPMC8851604 | biostudies-literature
| S-EPMC3731426 | biostudies-literature
| S-EPMC7525573 | biostudies-literature
| S-EPMC7109176 | biostudies-literature
| S-EPMC5859113 | biostudies-literature
| S-EPMC6449752 | biostudies-literature
| PRJNA700999 | ENA