Unknown

Dataset Information

0

Visualizing polymeric bioresorbable scaffolds with three-dimensional image reconstruction using contrast-enhanced micro-computed tomography.


ABSTRACT: There are no previous studies showing how to visualize polymeric bioresorbable scaffolds (BRSs) by micro-computed tomography (mCT). There are no previous studies showing how to visualize polymeric bioresorbable scaffolds (BRSs) by micro-computed tomography (mCT). This study aimed to explore the feasibility of detecting polymeric BRS with 3-dimensional reconstruction of BRS images by contrast-enhanced mCT and to determine the optimal imaging settings. BRSs, made of poly-L-lactic acid (PLLA), were implanted in coronary bifurcation models. Five treatments were conducted to examine an optimal condition for imaging BRSs: Baseline treatment, samples were filled with normal saline and scanned with mCT immediately; Treatment-1, -2, -3 and -4, samples were filled with contrast medium and scanned with mCT immediately and 1, 2 and 3 h thereafter, corresponding to soaking time of contrast medium of 0, 1, 2 and 3 h. Compared to Baseline, mCT scanning completely discriminate the scaffold struts from the vascular lumen immediately after filling the samples with contrast agent but not from the vascular wall until the contrast agent soaking time was more than 2 h (Treatment-3 and -4). By setting 10-15 HU as a cut-point of CT values, the scaffold strut detectable rate at Baseline and Teatment-1, -2, -3 and -4 were 1.23?±?0.31%, 1.65?±?0.26%, 58.14?±?12.84%, 97.97?±?1.43% and 98.90?±?0.38%, respectively (Treatment-3 vs. Treatment-2, p?

SUBMITTER: Tu S 

PROVIDER: S-EPMC5383680 | biostudies-literature | 2017 May

REPOSITORIES: biostudies-literature

altmetric image

Publications

Visualizing polymeric bioresorbable scaffolds with three-dimensional image reconstruction using contrast-enhanced micro-computed tomography.

Tu Sheng S   Hu Fudong F   Cai Wei W   Xiao Liyan L   Zhang Linlin L   Zheng Hong H   Jiang Qiong Q   Chen Lianglong L  

The international journal of cardiovascular imaging 20161230 5


There are no previous studies showing how to visualize polymeric bioresorbable scaffolds (BRSs) by micro-computed tomography (mCT). There are no previous studies showing how to visualize polymeric bioresorbable scaffolds (BRSs) by micro-computed tomography (mCT). This study aimed to explore the feasibility of detecting polymeric BRS with 3-dimensional reconstruction of BRS images by contrast-enhanced mCT and to determine the optimal imaging settings. BRSs, made of poly-L-lactic acid (PLLA), were  ...[more]

Similar Datasets

| S-EPMC5564335 | biostudies-literature
| S-EPMC6820559 | biostudies-literature
| S-EPMC4497654 | biostudies-literature
| S-EPMC3779602 | biostudies-literature
| S-EPMC5773475 | biostudies-literature
| S-EPMC4565718 | biostudies-literature
| S-EPMC10782945 | biostudies-literature
| S-EPMC5808659 | biostudies-other
| S-EPMC2841094 | biostudies-literature
| S-EPMC6292212 | biostudies-literature