Unknown

Dataset Information

0

Two degrees of freedom quasi-static EMG-force at the wrist using a minimum number of electrodes.


ABSTRACT: Surface electromyogram-controlled powered hand/wrist prostheses return partial upper-limb function to limb-absent persons. Typically, one degree of freedom (DoF) is controlled at a time, with mode switching between DoFs. Recent research has explored using large-channel EMG systems to provide simultaneous, independent and proportional (SIP) control of two joints-but such systems are not practical in current commercial prostheses. Thus, we investigated site selection of a minimum number of conventional EMG electrodes in an EMG-force task, targeting four sites for a two DoF controller. In a laboratory experiment with 10 able-bodied subjects and three limb-absent subjects, 16 electrodes were placed about the proximal forearm. Subjects produced 1-DoF and 2-DoF slowly force-varying contractions up to 30% maximum voluntary contraction (MVC). EMG standard deviation was related to forces via regularized regression. Backward stepwise selection was used to retain those progressively fewer electrodes that exhibited minimum error. For 1-DoF models using two retained electrodes (which mimics the current state of the art), subjects had average RMS errors of (depending on the DoF): 7.1-9.5% MVC for able-bodied and 13.7-17.1% MVC for limb-absent subjects. For 2-DoF models, subjects using four electrodes had errors on 1-DoF trials of 6.7-8.5% MVC for able-bodied and 11.9-14.0% MVC for limb-absent; and errors on 2-DoF trials of 9.9-11.2% MVC for able-bodied and 15.8-16.7% MVC for limb-absent subjects. For each model, retaining more electrodes did not statistically improve performance. The able-bodied results suggest that backward selection is a viable method for minimum error selection of as few as four electrode sites for these EMG-force tasks. Performance evaluation in a prosthesis control task is a necessary and logical next step for this site selection method.

SUBMITTER: Clancy EA 

PROVIDER: S-EPMC5481845 | biostudies-literature | 2017 Jun

REPOSITORIES: biostudies-literature

altmetric image

Publications

Two degrees of freedom quasi-static EMG-force at the wrist using a minimum number of electrodes.

Clancy Edward A EA   Martinez-Luna Carlos C   Wartenberg Marek M   Dai Chenyun C   Farrell Todd R TR  

Journal of electromyography and kinesiology : official journal of the International Society of Electrophysiological Kinesiology 20170329


Surface electromyogram-controlled powered hand/wrist prostheses return partial upper-limb function to limb-absent persons. Typically, one degree of freedom (DoF) is controlled at a time, with mode switching between DoFs. Recent research has explored using large-channel EMG systems to provide simultaneous, independent and proportional (SIP) control of two joints-but such systems are not practical in current commercial prostheses. Thus, we investigated site selection of a minimum number of convent  ...[more]

Similar Datasets

| S-EPMC6556412 | biostudies-literature
| S-EPMC8671403 | biostudies-literature
| S-EPMC10255999 | biostudies-literature
| S-EPMC4787623 | biostudies-literature
| S-EPMC8382987 | biostudies-literature
| S-EPMC4026794 | biostudies-literature
| S-EPMC8122016 | biostudies-literature
| S-EPMC6975923 | biostudies-literature
| S-EPMC7278014 | biostudies-literature
| S-EPMC6693558 | biostudies-literature