Enhancing the Angular Sensitivity of Plasmonic Sensors Using Hyperbolic Metamaterials.


ABSTRACT: Surface plasmon resonance (SPR) sensors operate mainly on prism and grating coupling techniques, with spectral and angular scans being the two major interrogation schemes. Among them, the angular scan technique has several advantages including higher measurement precision owing to its higher signal-to-noise ratio. The currently available SPR sensor arrangements provide a maximum angular sensitivity of 500°-600° per RIU. Here, we report the study of grating coupled-hyperbolic metamaterial (GC-HMM) sensors with high angular sensitivity. The experimental studies show extraordinary angular sensitivities from visible to near infrared (NIR) wavelengths by exciting bulk plasmon polaritons associated with hyperbolic metamaterials, with a maximum of 7000° per RIU. This angular-scan plasmonic biosensor has been used for the detection of low molecular weight biomolecules such as biotin (244 Da) and high molecular weight macromolecules such as Cowpea mosaic virus (CPMV, 5.6 × 106 Da) at ultralow concentrations. The miniaturized sensing device can be integrated with microfluidic systems for the development of next-generation biosensors for lab-on-a-chip and point-of-care applications.

SUBMITTER: Sreekanth KV 

PROVIDER: S-EPMC5482536 | biostudies-literature | 2016 Nov

REPOSITORIES: biostudies-literature

altmetric image

Publications

Enhancing the Angular Sensitivity of Plasmonic Sensors Using Hyperbolic Metamaterials.

Sreekanth Kandammathe Valiyaveedu KV   Alapan Yunus Y   ElKabbash Mohamed M   Wen Amy M AM   Ilker Efe E   Hinczewski Michael M   Gurkan Umut A UA   Steinmetz Nicole F NF   Strangi Giuseppe G  

Advanced optical materials 20160802 11


Surface plasmon resonance (SPR) sensors operate mainly on prism and grating coupling techniques, with spectral and angular scans being the two major interrogation schemes. Among them, the angular scan technique has several advantages including higher measurement precision owing to its higher signal-to-noise ratio. The currently available SPR sensor arrangements provide a maximum angular sensitivity of 500°-600° per RIU. Here, we report the study of grating coupled-hyperbolic metamaterial (GC-HMM  ...[more]

Similar Datasets

| S-EPMC4256712 | biostudies-other
| S-EPMC4959915 | biostudies-literature
| S-EPMC4040552 | biostudies-literature
| S-EPMC7292619 | biostudies-literature
| S-EPMC9232634 | biostudies-literature
| S-EPMC10665367 | biostudies-literature
| S-EPMC4073170 | biostudies-literature
| S-EPMC4743008 | biostudies-literature
| S-EPMC6195569 | biostudies-literature
| S-EPMC4833869 | biostudies-other