Microscale Quantitative Analysis of Polyhydroxybutyrate in Prokaryotes Using IDMS.


ABSTRACT: Poly(3-hydroxybutyrate) (PHB) is an interesting biopolymer for replacing petroleum-based plastics, its biological production is performed in natural and engineered microorganisms. Current metabolic engineering approaches rely on high-throughput strain construction and screening. Analytical procedures have to be compatible with the small scale and speed of these approaches. Here, we present a method based on isotope dilution mass spectrometry (IDMS) and propanolysis extraction of poly(3-hydroxybutyrate) from an Escherichia coli strain engineered for PHB production. As internal standard (IS), we applied an uniformly labeled 13C-cell suspension, of an E. coli PHB producing strain, grown on U-13C-glucose as C-source. This internal 13C-PHB standard enables to quantify low concentrations of PHB (LOD of 0.01 µg/gCDW) from several micrograms of biomass. With this method, a technical reproducibility of about 1.8% relative standard deviation is achieved. Furthermore, the internal standard is robust towards different sample backgrounds and dilutions. The early addition of the internal standard also enables higher reproducibility and increases sensitivity and throughput by simplified sample preparation steps.

SUBMITTER: Velasco Alvarez MI 

PROVIDER: S-EPMC5487990 | biostudies-literature | 2017 May

REPOSITORIES: biostudies-literature

altmetric image

Publications

Microscale Quantitative Analysis of Polyhydroxybutyrate in Prokaryotes Using IDMS.

Velasco Alvarez Mariana Itzel MI   Ten Pierick Angela A   van Dam Patricia T N PTN   Maleki Seifar Reza R   van Loosdrecht Mark C M MCM   Wahl S Aljoscha SA  

Metabolites 20170517 2


Poly(3-hydroxybutyrate) (PHB) is an interesting biopolymer for replacing petroleum-based plastics, its biological production is performed in natural and engineered microorganisms. Current metabolic engineering approaches rely on high-throughput strain construction and screening. Analytical procedures have to be compatible with the small scale and speed of these approaches. Here, we present a method based on isotope dilution mass spectrometry (IDMS) and propanolysis extraction of poly(3-hydroxybu  ...[more]

Similar Datasets

| S-EPMC5064372 | biostudies-literature
| S-EPMC5748938 | biostudies-literature
| S-EPMC3176501 | biostudies-literature
| S-EPMC5472229 | biostudies-literature
| S-EPMC3434783 | biostudies-literature
| S-EPMC9090908 | biostudies-literature
| S-EPMC2770534 | biostudies-literature
| S-EPMC8398664 | biostudies-literature
| S-EPMC5862892 | biostudies-literature
| S-EPMC7537788 | biostudies-literature