Polyethyleneimine-treated polyacrylonitrile membrane hemofilter for critically ill patients receiving anticoagulant-free prolonged intermittent renal replacement therapy: a single-center, prospective, self-controlled pilot study.


ABSTRACT: Critically ill patients requiring renal replacement therapy (RRT) are at risk of disease-related bleeding. Systemic heparinization should be avoided. AN69ST, a polyethyleneimine-treated polyacrylonitrile (AN69) membrane hemofilter, can be primed with heparin, improving its local anticoagulative activity. Prolonged intermittent RRT (PI-RRT) is of shorter duration and cheaper, considered as an alternative to continuous RRT. This study was performed to compare the success rate of anticoagulant-free PI-RRT using AN69ST versus AN69 membrane hemofilter. We also evaluated risk factors for filter clotting.This crossover, double-blind, randomized study included patients requiring PI-RRT but at high bleeding risk treated with AN69ST and AN69 hemo filters. The success rate of RRT, filter lifespan and severity of filter clotting were compared between the hemo filters. Factors associated with the filter clotting risk were analyzed with a Cox proportional hazards model.This study included 60 patients (mean age, 68.1 ± 15.8 years). Thirty-three (55.0%) patients were in the intensive care unit, 34 (56.8%) had disease-related thrombocytopenia, and 14 (23.3%) had local hemorrhagic diseases. The success rate of PI-RRT with the AN69ST and AN69 hemofilter was 51.7% and 50.9%, respectively (P > 0.05). The mean PI-RRT duration was 543.1 ± 119.0 min in the completed sessions and 387.3 ± 140.8 min in the prematurely terminated sessions, without significant difference between AN69ST and AN69 hemofilters. Cox regression analysis showed that age (odds ratio [OR], 1.023 per year), platelet count (OR, 1.07 per 10 × 109/L), hemoglobin concentration (OR, 1.035 per 1 g/L), and activated partial thromboplastin time (aPTT; OR, 0.973 per second) were associated with a hemofilter clotting risk. The AN69ST hemofilter lifespan was significantly prolonged averaging an extra 251.7 min in patients with an aPTT of <35.3 s, hemoglobin concentration of >83 g/L and platelet count of <70 × 109/L.Anticoagulant-free PI-RRT by a heparin-primed AN69ST hemofilter reached a 51.7% success rate. The risk of premature clotting of the extracorporeal circuit remains unsatisfactory. For select patients at high risk of bleeding, the heparin-primed AN69ST hemofilter may be more appropriate for anticoagulation-free PI-RRT.https://www.clinicaltrials.gov ; study number: NCT02355873 . Release Date 01/21/2015.

SUBMITTER: Su T 

PROVIDER: S-EPMC5493884 | biostudies-literature | 2017 Jun

REPOSITORIES: biostudies-literature

altmetric image

Publications

Polyethyleneimine-treated polyacrylonitrile membrane hemofilter for critically ill patients receiving anticoagulant-free prolonged intermittent renal replacement therapy: a single-center, prospective, self-controlled pilot study.

Su Tao T   Jin Qizhuang Q   Liu Zhongyuan Z  

BMC nephrology 20170630 1


<h4>Background</h4>Critically ill patients requiring renal replacement therapy (RRT) are at risk of disease-related bleeding. Systemic heparinization should be avoided. AN69ST, a polyethyleneimine-treated polyacrylonitrile (AN69) membrane hemofilter, can be primed with heparin, improving its local anticoagulative activity. Prolonged intermittent RRT (PI-RRT) is of shorter duration and cheaper, considered as an alternative to continuous RRT. This study was performed to compare the success rate of  ...[more]

Similar Datasets

| S-EPMC3409546 | biostudies-literature
| S-EPMC10900833 | biostudies-literature
| S-EPMC4974210 | biostudies-literature
| S-EPMC7268712 | biostudies-literature
| S-EPMC10367369 | biostudies-literature
| S-EPMC4173817 | biostudies-literature
| S-EPMC9724830 | biostudies-literature
| S-EPMC4633782 | biostudies-literature
| S-EPMC10785304 | biostudies-literature
| S-EPMC9867148 | biostudies-literature