Unknown

Dataset Information

0

Evaluation of realistic layouts for next generation on-scalp MEG: spatial information density maps.


ABSTRACT: While commercial magnetoencephalography (MEG) systems are the functional neuroimaging state-of-the-art in terms of spatio-temporal resolution, MEG sensors have not changed significantly since the 1990s. Interest in newer sensors that operate at less extreme temperatures, e.g., high critical temperature (high-T c) SQUIDs, optically-pumped magnetometers, etc., is growing because they enable significant reductions in head-to-sensor standoff (on-scalp MEG). Various metrics quantify the advantages of on-scalp MEG, but a single straightforward one is lacking. Previous works have furthermore been limited to arbitrary and/or unrealistic sensor layouts. We introduce spatial information density (SID) maps for quantitative and qualitative evaluations of sensor arrays. SID-maps present the spatial distribution of information a sensor array extracts from a source space while accounting for relevant source and sensor parameters. We use it in a systematic comparison of three practical on-scalp MEG sensor array layouts (based on high-T c SQUIDs) and the standard Elekta Neuromag TRIUX magnetometer array. Results strengthen the case for on-scalp and specifically high-T c SQUID-based MEG while providing a path for the practical design of future MEG systems. SID-maps are furthermore general to arbitrary magnetic sensor technologies and source spaces and can thus be used for design and evaluation of sensor arrays for magnetocardiography, magnetic particle imaging, etc.

SUBMITTER: Riaz B 

PROVIDER: S-EPMC5539206 | biostudies-literature | 2017 Aug

REPOSITORIES: biostudies-literature

altmetric image

Publications

Evaluation of realistic layouts for next generation on-scalp MEG: spatial information density maps.

Riaz Bushra B   Pfeiffer Christoph C   Schneiderman Justin F JF  

Scientific reports 20170801 1


While commercial magnetoencephalography (MEG) systems are the functional neuroimaging state-of-the-art in terms of spatio-temporal resolution, MEG sensors have not changed significantly since the 1990s. Interest in newer sensors that operate at less extreme temperatures, e.g., high critical temperature (high-T <sub>c</sub>) SQUIDs, optically-pumped magnetometers, etc., is growing because they enable significant reductions in head-to-sensor standoff (on-scalp MEG). Various metrics quantify the ad  ...[more]

Similar Datasets

| S-EPMC6870167 | biostudies-literature
| S-EPMC7262552 | biostudies-literature
| S-EPMC6096486 | biostudies-literature
| S-EPMC5256432 | biostudies-literature
| S-EPMC6445124 | biostudies-literature
| S-EPMC4118603 | biostudies-literature
| S-EPMC2875196 | biostudies-literature
| S-EPMC3070491 | biostudies-literature
| S-EPMC4839648 | biostudies-literature