Unknown

Dataset Information

0

Polymer-spray mass spectrometric detection and quantitation of hydrophilic compounds and some narcotics.


ABSTRACT: RATIONALE:High-throughput screening of biofluids is essential in monitoring concentration of a variety of drugs to determine their efficacy and toxicity. Organosiloxane polymers prepared by sol-gel chemistry as sample supports, and electrospray ionization emitters in a single material and as an alternative to paper substrates, is described in this study. METHODS:Hydrophobic drugs and hydrophilic streptomycin were analyzed by polymer-spray mass spectrometry with an LTQ-Orbitrap mass spectrometer. Drug samples in urine (1-2 ?L) were deposited on an OSX polymer, allowed to dry, then electrosprayed from the polymer tip into the mass spectrometer without sample pretreatment. The OSX polymers, whose polarity and porosity can be controlled, were prepared by sol-gel chemistry where methyl-substituted alkoxysilanes were hydrolyzed in the presence of a pore template and an acid catalyst. RESULTS:Five nanograms each of seven narcotic drugs were detected in <1 min (relative standard deviation (RSD) of response <1% for each drug). Calibration curves of cocaine and streptomycin in urine were used to establish the performance of the polymer. For sample 1 (n = 2), the mean recovery for cocaine was 81% with paper and 90% with polymer. Streptomycin is detected with polymer, not with paper; for samples 1 and 2 (n = 3), mean recovery was 97% and 95%, respectively. CONCLUSIONS:Organosiloxane polymers achieve more sensitive analysis than paper, allowing for more accurate quantitation of both hydrophobic and hydrophilic drug compounds. The ability to tailor the polymer polarity and porosity allows for the synthesis of a wide range of polymers, and thus opens many possibilities for further development and applications.

SUBMITTER: Dulay MT 

PROVIDER: S-EPMC5591076 | biostudies-literature | 2017 Oct

REPOSITORIES: biostudies-literature

altmetric image

Publications

Polymer-spray mass spectrometric detection and quantitation of hydrophilic compounds and some narcotics.

Dulay Maria T MT   Zare Richard N RN  

Rapid communications in mass spectrometry : RCM 20171001 19


<h4>Rationale</h4>High-throughput screening of biofluids is essential in monitoring concentration of a variety of drugs to determine their efficacy and toxicity. Organosiloxane polymers prepared by sol-gel chemistry as sample supports, and electrospray ionization emitters in a single material and as an alternative to paper substrates, is described in this study.<h4>Methods</h4>Hydrophobic drugs and hydrophilic streptomycin were analyzed by polymer-spray mass spectrometry with an LTQ-Orbitrap mas  ...[more]

Similar Datasets

| S-EPMC7606603 | biostudies-literature
| S-EPMC6822905 | biostudies-literature
| S-EPMC6790228 | biostudies-literature
| S-EPMC4232213 | biostudies-literature
| S-EPMC4082387 | biostudies-literature
| S-EPMC8675027 | biostudies-literature
| S-EPMC2959116 | biostudies-literature
| S-EPMC8278903 | biostudies-literature
| S-EPMC4802359 | biostudies-literature
| S-EPMC1138428 | biostudies-other