Unknown

Dataset Information

0

Exposure Modelling of Extremely Low-Frequency Magnetic Fields from Overhead Power Lines and Its Validation by Measurements.


ABSTRACT: A three-dimensional model for calculating long term exposure to extremely low-frequency magnetic fields from high-voltage overhead power lines is presented, as well as its validation by measurements. For the validation, the model was applied to two different high-voltage overhead power lines in Iffwil and Wiler (Switzerland). In order to capture the daily and seasonal variations, each measurement was taken for 48 h and the measurements were carried out six times at each site, at intervals of approximately two months, between January and December 2015. During each measurement, a lateral transect of the magnetic flux density was determined in the middle of a span from nine measurement points in the range of ±80 m. The technical data of both the lines as well as the load flow data during the measurement periods were provided by the grid operators. These data were used to calculate 48 h averages of the absolute value of the magnetic flux density and compared with modelled values. The highest 48 h average was 1.66 µT (centre of the line in Iffwil); the lowest 48 h average was 22 nT (80 m distance from the centre line in Iffwil). On average, the magnetic flux density was overestimated by 2% (standard deviation: 9%) in Iffwil and underestimated by 1% (8%) in Wiler. Sensitivity analyses showed that the uncertainty is mainly driven by errors in the coordinates and height data. In particular, for predictions near the centre of the line, an accurate digital terrain model is critical.

SUBMITTER: Burgi A 

PROVIDER: S-EPMC5615486 | biostudies-literature | 2017 Aug

REPOSITORIES: biostudies-literature

altmetric image

Publications

Exposure Modelling of Extremely Low-Frequency Magnetic Fields from Overhead Power Lines and Its Validation by Measurements.

Bürgi Alfred A   Sagar Sanjay S   Struchen Benjamin B   Joss Stefan S   Röösli Martin M  

International journal of environmental research and public health 20170823 9


A three-dimensional model for calculating long term exposure to extremely low-frequency magnetic fields from high-voltage overhead power lines is presented, as well as its validation by measurements. For the validation, the model was applied to two different high-voltage overhead power lines in Iffwil and Wiler (Switzerland). In order to capture the daily and seasonal variations, each measurement was taken for 48 h and the measurements were carried out six times at each site, at intervals of app  ...[more]

Similar Datasets

2022-05-05 | GSE166811 | GEO
| PRJNA702060 | ENA
2012-01-28 | GSE35371 | GEO
2012-01-28 | E-GEOD-35371 | biostudies-arrayexpress
| S-EPMC2667019 | biostudies-literature
| S-EPMC3828379 | biostudies-literature
| S-EPMC7014826 | biostudies-literature
| S-EPMC7745074 | biostudies-literature
| S-EPMC6068168 | biostudies-literature
| S-EPMC4154968 | biostudies-literature