Unknown

Dataset Information

0

Mid-Term Outcomes of Metal-Backed Unicompartmental Knee Arthroplasty Show Superiority to All-Polyethylene Unicompartmental and Total Knee Arthroplasty.


ABSTRACT: BACKGROUND:Two commonly used tibial designs for unicompartmental knee arthroplasty (UKA) are all-polyethylene "inlay" and metal-backed "onlay" components. Biomechanical studies showed that the metal baseplate in onlay designs better distributes forces over the tibia but studies failed to show differences in functional outcomes between both designs at mid-term follow-up. Furthermore, no studies have compared both designs with total knee arthroplasty (TKA). QUESTIONS/PURPOSES:The goal of this study was to compare outcomes of inlay UKA and onlay UKA at mid-term follow-up and compare these with TKA outcomes. METHODS:In this retrospective study, 52 patients undergoing inlay medial UKA, 59 patients undergoing onlay medial UKA, and 59 patients undergoing TKA were included. Western Ontario and McMaster Universities Arthritis Index scores were collected preoperatively and at mean 5.1-year follow-up (range 4.0-7.0 years). RESULTS:Preoperatively, no differences were observed in patient characteristics or outcome scores. At mid-term follow-up, patients undergoing onlay medial UKA reported significant better functional outcomes than those of inlay medial UKA (92.0 ± 10.4 vs. 82.4 ± 18.7, p = 0.010) and when compared to TKA (92.0 ± 10.4 vs. 79.6 ± 18.5, p < 0.001) while no significant differences between inlay medial UKA and TKA were noted. No significant differences in revision rates were found. CONCLUSION:Functional outcomes following onlay metal-backed medial UKA were significantly better compared to inlay all-polyethylene medial UKA and to TKA. Based on the results of this study and on biomechanical and survivorship studies in the literature, we recommended using metal-backed onlay tibial components for unicompartmental knee arthroplasty.

SUBMITTER: van der List JP 

PROVIDER: S-EPMC5617820 | biostudies-literature | 2017 Oct

REPOSITORIES: biostudies-literature

altmetric image

Publications

Mid-Term Outcomes of Metal-Backed Unicompartmental Knee Arthroplasty Show Superiority to All-Polyethylene Unicompartmental and Total Knee Arthroplasty.

van der List Jelle P JP   Kleeblad Laura J LJ   Zuiderbaan Hendrik A HA   Pearle Andrew D AD  

HSS journal : the musculoskeletal journal of Hospital for Special Surgery 20170512 3


<h4>Background</h4>Two commonly used tibial designs for unicompartmental knee arthroplasty (UKA) are all-polyethylene "inlay" and metal-backed "onlay" components. Biomechanical studies showed that the metal baseplate in onlay designs better distributes forces over the tibia but studies failed to show differences in functional outcomes between both designs at mid-term follow-up. Furthermore, no studies have compared both designs with total knee arthroplasty (TKA).<h4>Questions/purposes</h4>The go  ...[more]

Similar Datasets

| S-EPMC6066763 | biostudies-literature
| S-EPMC6844393 | biostudies-literature
| S-EPMC6117028 | biostudies-literature
| S-EPMC10324271 | biostudies-literature
| S-EPMC3809509 | biostudies-literature
| S-EPMC7303496 | biostudies-literature
| S-EPMC2311492 | biostudies-other
| S-EPMC7768953 | biostudies-literature
| S-EPMC10104836 | biostudies-literature
| S-EPMC8019176 | biostudies-literature