Unknown

Dataset Information

0

Fluoroscopic Technique for Open Reduction and Internal Fixation of Proximal Humeral Fracture Using the Proximal Humeral Locking Plate: Proposal of "Plate" and "Screw" Views.


ABSTRACT: Proximal humeral fractures are common injuries with increasing incidence, particularly in the aging population. Nondisplaced or minimally displaced fractures can be treated conservatively whereas surgical fixation is usually indicated in the cases of displaced fractures. Various surgical options have been used for treatment of these fractures. Good outcomes have been reported with use of the Proximal Humeral Internal Locking System (PHILOS plate; Synthes, Zuchwil, Switzerland) as the implant of choice. However many complications have been reported, including varus malalignment, excessive retroversion of the articular part of the humerus, penetration of screws, and avascular necrosis of the humeral head. Therefore, we have hypothesized that an inadequate intraoperative fluoroscopic assessment may be an important factor contributing to these complications. We have described a step-by-step intraoperative fluoroscopic setup, including the proposal of a plate and screw view, focusing on the accuracy of reduction and proper placement of the PHILOS plate to prevent the complications previously described.

SUBMITTER: Kanchanatawan W 

PROVIDER: S-EPMC5621472 | biostudies-literature | 2017 Aug

REPOSITORIES: biostudies-literature

altmetric image

Publications

Fluoroscopic Technique for Open Reduction and Internal Fixation of Proximal Humeral Fracture Using the Proximal Humeral Locking Plate: Proposal of "Plate" and "Screw" Views.

Kanchanatawan Wichan W   Suppauksorn Sunikom S   Densiri-Aksorn Worawit W   Kittithamvongs Piyabuth P   Pongpinyopap Warongporn W  

Arthroscopy techniques 20170710 4


Proximal humeral fractures are common injuries with increasing incidence, particularly in the aging population. Nondisplaced or minimally displaced fractures can be treated conservatively whereas surgical fixation is usually indicated in the cases of displaced fractures. Various surgical options have been used for treatment of these fractures. Good outcomes have been reported with use of the Proximal Humeral Internal Locking System (PHILOS plate; Synthes, Zuchwil, Switzerland) as the implant of  ...[more]

Similar Datasets

| S-EPMC4738638 | biostudies-literature
| S-EPMC7413303 | biostudies-literature
| S-EPMC2266656 | biostudies-other
| S-EPMC6491912 | biostudies-literature