Standardized Approach for ROI-Based Measurements of Proton Density Fat Fraction and R2* in the Liver.


ABSTRACT: OBJECTIVE:The purpose of this study was to evaluate the reproducibility (interreviewer agreement) and repeatability (intrareviewer agreement) of ROI sampling strategies to measure chemical shift-encoded (CSE) MRI-based liver proton density fat fraction (PDFF) and R2* (1 / T2*). A secondary purpose was to standardize ROI-based liver PDFF and R2* measurements by providing a compromise between measurement reproducibility and repeatability and time burden for image analysts. MATERIALS AND METHODS:CSE data from two cohorts were retrospectively analyzed. Cohort A included 53 patients referred for abdominal MRI and healthy subjects recruited for a comparison study of CT and MRI. Cohort B included 37 patients with suspected liver iron overload. Three reviewers measured liver PDFF and R2* using previously reported ROI sampling strategies. Inter- and intrareviewer agreement of liver PDFF and R2* were evaluated using Bland-Altman analysis. RESULTS:Averaging largest-fit ROIs over the nine Couinaud segments resulted in the narrowest limits of agreement (LOA) for liver PDFF and R2* measurements in both cohorts. For PDFF, interreviewer agreement had mean LOA of ± 0.8% for cohort A and ± 1.7% for cohort B. Intrareviewer agreement was ± 0.5% for cohort A and ± 0.9% for cohort B. For R2* interre-viewer agreement had mean LOA of ± 3.0 s-1 for cohort A and ± 17.9 s-1 for cohort B. Intrare-viewer agreement was ± 2.6 s-1 for cohort A and ± 14.6 s-1 for cohort B. This approach was the most time-burdensome, requiring a mean ± SD of 149.7 ± 8.6 s per dataset. CONCLUSION:For improved reproducibility and repeatability of liver PDFF and R2* measurements, clinicians and researchers should sample as much area of the liver as possible using multiple large ROIs.

SUBMITTER: Campo CA 

PROVIDER: S-EPMC5639884 | biostudies-literature | 2017 Sep

REPOSITORIES: biostudies-literature

altmetric image

Publications

Standardized Approach for ROI-Based Measurements of Proton Density Fat Fraction and R2* in the Liver.

Campo Camilo A CA   Hernando Diego D   Schubert Tilman T   Bookwalter Candice A CA   Pay Andrew J Van AJV   Reeder Scott B SB  

AJR. American journal of roentgenology 20170713 3


<h4>Objective</h4>The purpose of this study was to evaluate the reproducibility (interreviewer agreement) and repeatability (intrareviewer agreement) of ROI sampling strategies to measure chemical shift-encoded (CSE) MRI-based liver proton density fat fraction (PDFF) and R2* (1 / T2*). A secondary purpose was to standardize ROI-based liver PDFF and R2* measurements by providing a compromise between measurement reproducibility and repeatability and time burden for image analysts.<h4>Materials and  ...[more]

Similar Datasets

| S-EPMC6449180 | biostudies-literature
| S-EPMC5813433 | biostudies-literature
| S-EPMC6895403 | biostudies-literature
| S-EPMC10711480 | biostudies-literature
| S-EPMC6211296 | biostudies-literature
| S-EPMC10635941 | biostudies-literature
| S-EPMC6857925 | biostudies-literature
| S-EPMC3632805 | biostudies-other
| S-EPMC6090543 | biostudies-literature
| S-EPMC5571698 | biostudies-literature