Unknown

Dataset Information

0

Analysis of Photoirradiated Water Accommodated Fractions of Crude Oils Using Tandem TIMS and FT-ICR MS.


ABSTRACT: For the first time, trapped ion mobility spectrometry (TIMS) in tandem with Fourier transform ion cyclotron resonance mass spectrometry (FT-ICR MS) is applied to the analysis of the low energy water accommodated fraction (WAF) of a crude oil as a function of the exposure to light. The TIMS-FT-ICR MS analysis provided, in addition to the heteroatom series identification, new insights into the WAF isomeric complexity (e.g., [m/z; chemical formula; collision cross section] data sets) for a better evaluation of the degree of chemical and structural photoinduced transformations. Inspection of the [m/z; chemical formula; collision cross section] data sets shows that the WAF composition changes as a function of the exposure to light in the first 115 h by initial photosolubilization of HC components and their photo-oxidation up to O4-5 of mainly high double bond equivalence species (DBE > 9). The addition of high resolution TIMS (resolving power of 90-220) to ultrahigh resolution FT-ICR MS (resolving power over 400k) permitted the identification of a larger number of molecular components in a single analysis (e.g., over 47k using TIMS-MS compared to 12k by MS alone), with instances of over 6-fold increase in the number of molecular features per nominal mass due to the WAF isomeric complexity. This work represents a stepping stone toward a better understanding of the WAF components and highlights the need for better experimental and theoretical approaches to characterize the WAF structural diversity.

SUBMITTER: Benigni P 

PROVIDER: S-EPMC5661887 | biostudies-literature | 2017 Jun

REPOSITORIES: biostudies-literature

altmetric image

Publications

Analysis of Photoirradiated Water Accommodated Fractions of Crude Oils Using Tandem TIMS and FT-ICR MS.

Benigni Paolo P   Sandoval Kathia K   Thompson Christopher J CJ   Ridgeway Mark E ME   Park Melvin A MA   Gardinali Piero P   Fernandez-Lima Francisco F  

Environmental science & technology 20170509 11


For the first time, trapped ion mobility spectrometry (TIMS) in tandem with Fourier transform ion cyclotron resonance mass spectrometry (FT-ICR MS) is applied to the analysis of the low energy water accommodated fraction (WAF) of a crude oil as a function of the exposure to light. The TIMS-FT-ICR MS analysis provided, in addition to the heteroatom series identification, new insights into the WAF isomeric complexity (e.g., [m/z; chemical formula; collision cross section] data sets) for a better e  ...[more]

Similar Datasets

| S-EPMC4556654 | biostudies-literature
| S-EPMC10557258 | biostudies-literature
| S-EPMC8059610 | biostudies-literature
| S-EPMC4144182 | biostudies-literature
| S-EPMC3712280 | biostudies-literature
| S-EPMC3411821 | biostudies-literature
| S-EPMC5827162 | biostudies-literature
| S-EPMC10864312 | biostudies-literature
| S-EPMC7355774 | biostudies-literature
| S-EPMC6617137 | biostudies-literature