Unknown

Dataset Information

0

Comparative analysis of the visual performance after implantation of the toric implantable collamer lens in stable keratoconus: a 4-year follow-up after sequential procedure (CXL+TICL implantation).


ABSTRACT: Aims:To report on 4-year postoperative visual performance with the toric implantable collamer lens (TICL) for stable keratoconus after sequential procedure (corneal collagen crosslinking plus TICL implantation). Methods:Forty eyes of 24 patients with stable keratoconus with myopia between 0.00 and -18.00 dioptres (D) and astigmatism between 1.25 and 8.00 D were evaluated in this prospective interventional study (https://clinicaltrials.gov/ct2/show/NCT02833649). We evaluated refraction, visual outcomes, astigmatic changes analysed by Alpins vector, contrast sensitivity, aberrometry, modulation transfer functions (MTFs), defocus curve, and operative and postoperative complications. Results:At 4-year follow-up, 45% had 20/20 vision or better and 100% had 20/40 or better uncorrected visual acuity (UCVA). Vector analysis of refractive astigmatism shows that the surgically induced astigmatism (SIA) (3.20±1.46 D) was not significantly different from the target induced astigmatism (TIA) (3.14±1.42 D) (p=0.620). At 4 years postoperatively, none of the eyes showed a decrease in UCVA, in contrast to 24 eyes in which UCVA was increased by ?1 lines, with contrast sensitivity and improvement in total aberrations and MTF value at 5 per degree (*p=0.004) after TICL implantation. The cumulative 4-year corneal endothelial cell loss was ?5%. No patients reported dissatisfaction. At the end of follow-up, the vault was 658±54.33m (range, 500-711) and the intraocular pressure was 11.7±2.08 mm Hg. Occurrences of glare and night-driving troubles diminished after TICL surgery. Conclusion:The results from this standardised clinical investigation support TICL implantation from clinical and optical viewpoints in patients with stable keratoconus. Trial registration number:NCT02833649, Pre-results.

SUBMITTER: Doroodgar F 

PROVIDER: S-EPMC5721648 | biostudies-literature | 2017

REPOSITORIES: biostudies-literature

altmetric image

Publications

Comparative analysis of the visual performance after implantation of the toric implantable collamer lens in stable keratoconus: a 4-year follow-up after sequential procedure (CXL+TICL implantation).

Doroodgar Farideh F   Niazi Feazollah F   Sanginabadi Azad A   Niazi Sana S   Baradaran-Rafii Alireza A   Alinia Cyrus C   Azargashb Eznollah E   Ghoreishi Mohammad M  

BMJ open ophthalmology 20170928 1


<h4>Aims</h4>To report on 4-year postoperative visual performance with the toric implantable collamer lens (TICL) for stable keratoconus after sequential procedure (corneal collagen crosslinking plus TICL implantation).<h4>Methods</h4>Forty eyes of 24 patients with stable keratoconus with myopia between 0.00 and -18.00 dioptres (D) and astigmatism between 1.25 and 8.00 D were evaluated in this prospective interventional study (https://clinicaltrials.gov/ct2/show/NCT02833649). We evaluated refrac  ...[more]

Similar Datasets

| S-EPMC10161410 | biostudies-literature
| S-EPMC10435081 | biostudies-literature
| S-EPMC5573270 | biostudies-literature
| S-EPMC4130551 | biostudies-literature
| S-EPMC9756683 | biostudies-literature
| S-EPMC8843229 | biostudies-literature
| S-EPMC7391088 | biostudies-literature
| S-EPMC8101126 | biostudies-literature
| S-EPMC10957066 | biostudies-literature
| S-EPMC4816352 | biostudies-other