Unknown

Dataset Information

0

An MR-Based Model for Cardio-Respiratory Motion Compensation of Overlays in X-Ray Fluoroscopy.


ABSTRACT: In X-ray fluoroscopy, static overlays are used to visualize soft tissue. We propose a system for cardiac and respiratory motion compensation of these overlays. It consists of a 3-D motion model created from real-time magnetic resonance (MR) imaging. Multiple sagittal slices are acquired and retrospectively stacked to consistent 3-D volumes. Slice stacking considers cardiac information derived from the ECG and respiratory information extracted from the images. Additionally, temporal smoothness of the stacking is enhanced. Motion is estimated from the MR volumes using deformable 3-D/3-D registration. The motion model itself is a linear direct correspondence model using the same surrogate signals as slice stacking. In X-ray fluoroscopy, only the surrogate signals need to be extracted to apply the motion model and animate the overlay in real time. For evaluation, points are manually annotated in oblique MR slices and in contrast-enhanced X-ray images. The 2-D Euclidean distance of these points is reduced from 3.85 to 2.75 mm in MR and from 3.0 to 1.8 mm in X-ray compared with the static baseline. Furthermore, the motion-compensated overlays are shown qualitatively as images and videos.

SUBMITTER: Fischer P 

PROVIDER: S-EPMC5750091 | biostudies-literature | 2018 Jan

REPOSITORIES: biostudies-literature

altmetric image

Publications

An MR-Based Model for Cardio-Respiratory Motion Compensation of Overlays in X-Ray Fluoroscopy.

Fischer Peter P   Faranesh Anthony A   Pohl Thomas T   Maier Andreas A   Rogers Toby T   Ratnayaka Kanishka K   Lederman Robert R   Hornegger Joachim J  

IEEE transactions on medical imaging 20170704 1


In X-ray fluoroscopy, static overlays are used to visualize soft tissue. We propose a system for cardiac and respiratory motion compensation of these overlays. It consists of a 3-D motion model created from real-time magnetic resonance (MR) imaging. Multiple sagittal slices are acquired and retrospectively stacked to consistent 3-D volumes. Slice stacking considers cardiac information derived from the ECG and respiratory information extracted from the images. Additionally, temporal smoothness of  ...[more]

Similar Datasets

| S-EPMC5763408 | biostudies-literature
| S-EPMC7357965 | biostudies-literature
| S-EPMC5040623 | biostudies-literature
| S-EPMC5414502 | biostudies-literature
| S-EPMC6220806 | biostudies-literature
| S-EPMC6126443 | biostudies-literature
| S-EPMC3971824 | biostudies-other
| S-EPMC7007962 | biostudies-literature
| S-EPMC8357006 | biostudies-literature
| S-EPMC4065602 | biostudies-literature