Determination of torasemide in human plasma and its bioequivalence study by high-performance liquid chromatography with electrospray ionization tandem mass spectrometry.


ABSTRACT: A sensitive and selective method using high-performance liquid chromatography coupled with electrospray ionization tandem mass spectrometry (HPLC-ESI-MS) to determine the concentration of torasemide in human plasma samples was developed and validated. Tolbutamide was chosen as the internal standard (IS). The chromatography was performed on a Gl Sciences Inertsil ODS-3 column (100 mm×2.1 mm i.d., 5.0 µm) within 5 min, using methanol with 10 mM ammonium formate (60:40, v/v) as mobile phase at a flow rate of 0.2 mL/min. The targeted compound was detected in negative ionization at m/z 347.00 for torasemide and 269.00 for IS. The linearity range of this method was found to be within the concentration range of 1-2500 ng/mL (r=0.9984) for torasemide in human plasma. The accuracy of this measurement was between 94.05% and 103.86%. The extracted recovery efficiency was from 84.20% to 86.47% at three concentration levels. This method was also successfully applied in pharmacokinetics and bioequivalence studies in Chinese volunteers.

SUBMITTER: Zhang L 

PROVIDER: S-EPMC5762444 | biostudies-literature | 2016 Apr

REPOSITORIES: biostudies-literature

altmetric image

Publications

Determination of torasemide in human plasma and its bioequivalence study by high-performance liquid chromatography with electrospray ionization tandem mass spectrometry.

Zhang Lin L   Wang Rulin R   Tian Yuan Y   Zhang Zunjian Z  

Journal of pharmaceutical analysis 20151111 2


A sensitive and selective method using high-performance liquid chromatography coupled with electrospray ionization tandem mass spectrometry (HPLC-ESI-MS) to determine the concentration of torasemide in human plasma samples was developed and validated. Tolbutamide was chosen as the internal standard (IS). The chromatography was performed on a Gl Sciences Inertsil ODS-3 column (100 mm×2.1 mm i.d., 5.0 µm) within 5 min, using methanol with 10 mM ammonium formate (60:40, v/v) as mobile phase at a fl  ...[more]

Similar Datasets

| S-EPMC4551553 | biostudies-literature
| S-EPMC4062842 | biostudies-literature
| S-EPMC6332349 | biostudies-literature
| S-EPMC3290520 | biostudies-literature
| S-EPMC7503312 | biostudies-literature
| S-EPMC3277681 | biostudies-literature
| S-EPMC3665945 | biostudies-literature
| S-EPMC5762601 | biostudies-literature
| S-EPMC2876209 | biostudies-literature
| S-EPMC9379334 | biostudies-literature