Automated Microfluidic Droplet-Based Sample Chopper for Detection of Small Fluorescence Differences Using Lock-In Analysis.


ABSTRACT: Fluorescence is widely used for small-volume analysis and is a primary tool for on-chip detection in microfluidic devices, yet additional expertise, more elaborate optics, and phase-locked detectors are needed for ultrasensitive measurements. Recently, we designed a microfluidic analog to an optical beam chopper (?Chopper) that alternated formation of picoliter volume sample and reference droplets. Without complex optics, the device negated large signal drifts (1/f noise), allowing absorbance detection in a mere 27 ?m optical path. Here, we extend the ?Chopper concept to fluorescence detection with standard wide-field microscope optics. Precision of droplet control in the ?Chopper was improved by automation with pneumatic valves, allowing fluorescence measurements to be strictly phase locked at 0.04 Hz bandwidth to droplets generated at 3.50 Hz. A detection limit of 12 pM fluorescein was achieved when sampling 20 droplets, and as few as 310 zeptomoles (3.1 × 10-19 mol) were detectable in single droplets (8.8 nL). When applied to free fatty acid (FFA) uptake in 3T3-L1 adipocytes, this ?Chopper permitted single-cell FFA uptake rates to be quantified at 3.5 ± 0.2 × 10-15 mol cell-1 for the first time. Additionally, homogeneous immunoassays in droplets exhibited insulin detection limits of 9.3 nM or 190 amol (1.9 × 10-16 mol). The combination of this novel, automated ?Chopper with lock-in detection provides a high-performance platform for detecting small differences with standard fluorescence optics, particularly in situations where sample volume is limited. The technique should be simple to implement into a variety of other droplet fluidics devices.

SUBMITTER: Negou JT 

PROVIDER: S-EPMC5789453 | biostudies-literature | 2017 Jun

REPOSITORIES: biostudies-literature

altmetric image

Publications

Automated Microfluidic Droplet-Based Sample Chopper for Detection of Small Fluorescence Differences Using Lock-In Analysis.

Negou Jean T JT   Avila L Adriana LA   Li Xiangpeng X   Hagos Tesfagebriel M TM   Easley Christopher J CJ  

Analytical chemistry 20170511 11


Fluorescence is widely used for small-volume analysis and is a primary tool for on-chip detection in microfluidic devices, yet additional expertise, more elaborate optics, and phase-locked detectors are needed for ultrasensitive measurements. Recently, we designed a microfluidic analog to an optical beam chopper (μChopper) that alternated formation of picoliter volume sample and reference droplets. Without complex optics, the device negated large signal drifts (1/f noise), allowing absorbance de  ...[more]

Similar Datasets

| S-EPMC8748334 | biostudies-literature
| S-EPMC6190347 | biostudies-literature
| S-EPMC6493727 | biostudies-literature
| S-EPMC5290157 | biostudies-literature
| S-EPMC4902300 | biostudies-literature
| S-EPMC10745919 | biostudies-literature
| S-EPMC3977839 | biostudies-other
| S-EPMC7344826 | biostudies-literature
| S-EPMC3697795 | biostudies-literature
| S-EPMC6234046 | biostudies-literature