Unknown

Dataset Information

0

Lymphatic function measurements influenced by contrast agent volume and body position.


ABSTRACT: Several imaging modalities have been used to assess lymphatic function, including fluorescence microscopy, near-infrared fluorescence (NIRF) imaging, and Doppler optical coherence tomography (DOCT). They vary in how the mouse is positioned, the invasiveness of the experimental setup, and the volume of contrast agent injected. Here, we present how each of these experimental parameters affects functional measurements of collecting lymphatic vessels. First, fluorescence microscopy showed that supine mice have a statistically lower contraction frequency compared with mice sitting upright. To assess the effect of different injection volumes on these endpoints, mice were injected with 4, 10, or 20 ?l of dye. The lowest frequencies were observed after 20-?l injections. Interestingly, lymph-flow DOCT revealed that although there was lower contraction frequency in mice injected with 20 ?l versus 4 ?l, mice showed a higher volumetric flow with a 20-?l injection. This indicates that contraction frequency alone is not sufficient to understand lymphatic transport. Finally, NIRF revealed that removing the skin reduced contraction frequency. Therefore, this study reveals how sensitive these techniques are to mouse position, removal of skin, and dye volume. Care should be taken when comparing results obtained under different experimental conditions.

SUBMITTER: Bouta EM 

PROVIDER: S-EPMC5821192 | biostudies-literature | 2018 Jan

REPOSITORIES: biostudies-literature

altmetric image

Publications

Lymphatic function measurements influenced by contrast agent volume and body position.

Bouta Echoe M EM   Blatter Cedric C   Ruggieri Thomas A TA   Meijer Eelco Fj EF   Munn Lance L LL   Vakoc Benjamin J BJ   Padera Timothy P TP  

JCI insight 20180125 2


Several imaging modalities have been used to assess lymphatic function, including fluorescence microscopy, near-infrared fluorescence (NIRF) imaging, and Doppler optical coherence tomography (DOCT). They vary in how the mouse is positioned, the invasiveness of the experimental setup, and the volume of contrast agent injected. Here, we present how each of these experimental parameters affects functional measurements of collecting lymphatic vessels. First, fluorescence microscopy showed that supin  ...[more]

Similar Datasets

| S-EPMC7820935 | biostudies-literature
| S-EPMC8121940 | biostudies-literature
| S-EPMC6785385 | biostudies-literature
| S-EPMC3215051 | biostudies-literature
| S-EPMC3982083 | biostudies-other
| S-EPMC4967444 | biostudies-literature
| S-EPMC3192228 | biostudies-other
| S-EPMC6180369 | biostudies-literature
| S-EPMC7726088 | biostudies-literature
| S-EPMC8208422 | biostudies-literature