Unknown

Dataset Information

0

Tumor Contrast Enhancement and Whole-Body Elimination of the Manganese-Based Magnetic Resonance Imaging Contrast Agent Mn-PyC3A.


ABSTRACT: OBJECTIVES:The goals of this study were to compare the efficacy of the new manganese-based magnetic resonance imaging (MRI) contrast agent Mn-PyC3A to the commercial gadolinium-based agents Gd-DOTA and to Gd-EOB-DTPA to detect tumors in murine models of breast cancer and metastatic liver disease, respectively, and to quantify the fractional excretion and elimination of Mn-PyC3A in rats. METHODS:T1-weighted contrast-enhanced MRI with 0.1 mmol/kg Mn-PyC3A was compared with 0.1 mmol/kg Gd-DOTA in a breast cancer mouse model (n = 8) and to 0.025 mmol/kg Gd-EOB-DTPA in a liver metastasis mouse model (n = 6). The fractional excretion, 1-day biodistribution, and 7-day biodistribution in rats after injection of 2.0 mmol/kg [Mn]Mn-PyC3A or Gd-DOTA were quantified by Mn gamma counting or Gd elemental analysis. Imaging data were compared with a paired t test; biodistribution data were compared with an unpaired t test. RESULTS:The postinjection-preinjection increases in tumor-to-muscle contrast-to-noise ratio (?CNR) 3 minutes after injection of Mn-PyC3A and Gd-DOTA (mean ± standard deviation) were 17 ± 3.8 and 20 ± 4.4, respectively (P = 0.34). Liver-to-tumor ?CNR values at 8 minutes postinjection of Mn-PyC3A and Gd-EOB-DTPA were 28 ± 9.0 and 48 ± 23, respectively (P = 0.11). Mn-PyC3A is eliminated with 85% into the urine and 15% into the feces after administration to rats. The percentage of the injected doses (%ID) of Mn and Gd recovered in tissues after 1 day were 0.32 ± 0.12 and 0.57 ± 0.12, respectively (P = 0.0030), and after 7 days were 0.058 ± 0.051 and 0.19 ± 0.052, respectively (P < 0.0001). CONCLUSIONS:Mn-PyC3A provides comparable tumor contrast enhancement to Gd-DOTA in a mouse breast cancer model and is more completely eliminated than Gd-DOTA; partial hepatobiliary elimination of Mn-PyC3A enables conspicuous delayed phase visualization of liver metastases.

SUBMITTER: Erstad DJ 

PROVIDER: S-EPMC6785385 | biostudies-literature | 2019 Nov

REPOSITORIES: biostudies-literature

altmetric image

Publications

Tumor Contrast Enhancement and Whole-Body Elimination of the Manganese-Based Magnetic Resonance Imaging Contrast Agent Mn-PyC3A.

Erstad Derek J DJ   Ramsay Ian A IA   Jordan Veronica Clavijo VC   Sojoodi Mozhdeh M   Fuchs Bryan C BC   Tanabe Kenneth K KK   Caravan Peter P   Gale Eric M EM  

Investigative radiology 20191101 11


<h4>Objectives</h4>The goals of this study were to compare the efficacy of the new manganese-based magnetic resonance imaging (MRI) contrast agent Mn-PyC3A to the commercial gadolinium-based agents Gd-DOTA and to Gd-EOB-DTPA to detect tumors in murine models of breast cancer and metastatic liver disease, respectively, and to quantify the fractional excretion and elimination of Mn-PyC3A in rats.<h4>Methods</h4>T1-weighted contrast-enhanced MRI with 0.1 mmol/kg Mn-PyC3A was compared with 0.1 mmol/  ...[more]

Similar Datasets

| S-EPMC8596607 | biostudies-literature
| S-EPMC6939894 | biostudies-literature
| S-EPMC2771752 | biostudies-literature
| S-EPMC9285043 | biostudies-literature
| S-EPMC4841792 | biostudies-literature
| S-EPMC3086979 | biostudies-literature
| S-EPMC5884311 | biostudies-literature
| S-EPMC7053506 | biostudies-literature
| S-EPMC8792502 | biostudies-literature
| S-EPMC7897303 | biostudies-literature