Unknown

Dataset Information

0

A comparison of 10 accelerometer non-wear time criteria and logbooks in children.


ABSTRACT: There are many unresolved issues regarding data reduction algorithms for accelerometry. The choice of criterion for removal of non-wear time might have a profound influence on physical activity (PA) and sedentary time (SED) estimates. The aim of the present study was to compare 10 different non-wear criteria and a log of non-wear periods in 11-year-old children.Children from the Active Smarter Kids study performed 7-days of hip-worn accelerometer monitoring (Actigraph GT3X+) and logged the number of non-wear periods each day, along with the approximate duration and reason for non-wear. Accelerometers were analyzed using 10 different non-wear criteria: ? 10, 20, 30, 45, 60, and 90 min of consecutive zero counts without allowance for interruptions, and ?60 and 90 min with allowance for 1 and 2 min of interruptions.891 children provided 5203 measurement days, and reported 1232 non-wear periods ranging from 0 to 3 periods per day: on most days children reported no non-wear periods (77.1% of days). The maximum number of non-wear periods per day was 2 for the 90-min criterion, 3 to 5 for most criteria, 7 for the 20-min criterion, and 20 for the 10-min criterion. The non-wear criteria influenced overall PA (mean values across all criteria: 591 to 649 cpm; 10% difference) and SED time (461 to 539 min/day; 17% difference) estimates, especially for the most prolonged SED bouts. Estimates were similar for time spent in intensity-specific (light, moderate, vigorous, and moderate-to-vigorous) PA, but varied 6-9% among the non-wear criteria for proportions of time spent in intensity-specific PA (% of total wear time).Population level estimates of PA and SED differed between different accelerometer non-wear criteria, meaning that non-wear time algorithms should be standardized across studies to reduce confusion and improve comparability of children's PA level. Based on the numbers and reasons for non-wear periods, we suggest a 45 or 60-min consecutive zero count-criterion not allowing any interruptions to be applied in future pediatric studies, at least for children older than 10 years.The study is registered in Clinicaltrials.gov with identification number NCT02132494 . Registered 7 April 2014.

SUBMITTER: Aadland E 

PROVIDER: S-EPMC5840816 | biostudies-literature | 2018 Mar

REPOSITORIES: biostudies-literature

altmetric image

Publications

A comparison of 10 accelerometer non-wear time criteria and logbooks in children.

Aadland Eivind E   Andersen Lars Bo LB   Anderssen Sigmund Alfred SA   Resaland Geir Kåre GK  

BMC public health 20180306 1


<h4>Background</h4>There are many unresolved issues regarding data reduction algorithms for accelerometry. The choice of criterion for removal of non-wear time might have a profound influence on physical activity (PA) and sedentary time (SED) estimates. The aim of the present study was to compare 10 different non-wear criteria and a log of non-wear periods in 11-year-old children.<h4>Methods</h4>Children from the Active Smarter Kids study performed 7-days of hip-worn accelerometer monitoring (Ac  ...[more]

Similar Datasets

| S-EPMC6444637 | biostudies-literature
| S-EPMC9141158 | biostudies-literature
| S-EPMC3184184 | biostudies-literature
| S-EPMC3753482 | biostudies-literature
| S-EPMC8065130 | biostudies-literature
| S-EPMC5756085 | biostudies-literature
| S-EPMC5844092 | biostudies-literature
| S-EPMC7296937 | biostudies-literature
| S-EPMC4247661 | biostudies-literature
| S-EPMC4777377 | biostudies-literature