Retrospective dosimetry study of intensity-modulated radiation therapy for nasopharyngeal carcinoma: measurement-guided dose reconstruction and analysis.


ABSTRACT: BACKGROUND:Conventional phantom-based planar dosimetry (2D-PBD) quality assurance (QA) using gamma pass rate (GP (%)) is inadequate to reflect clinically relevant dose error in intensity-modulated radiation therapy (IMRT), owing to a lack of information regarding patient anatomy and volumetric dose distribution. This study aimed to evaluate the dose distribution accuracy of IMRT delivery for nasopharyngeal carcinoma (NPC), which passed the 2D-PBD verification, using a measurement-guided 3D dose reconstruction (3D-MGR) method. METHODS:Radiation treatment plans of 30 NPC cases and their pre-treatment 2D-PBD data were analyzed. 3D dose distribution was reconstructed on patient computed tomography (CT) images using the 3DVH software and compared to the treatment plans. Global and organ-specific dose GP (%), and dose-volume histogram (DVH) deviation of each structure was evaluated. Interdependency between GP (%) and the deviation of the volumetric dose was studied through correlation analysis. RESULTS:The 3D-MGR achieved global GP (%) similar to conventional 2D-PBD in the same criteria. However, structure-specific GP (%) significantly decreased under stricter criteria, including the planning target volume (PTV). The average deviation of all inspected dose volumes (DV) and volumetric dose (VD) parameters ranged from -?2.93% to 1.17%, with the largest negative deviation in V100% of the PTVnx of -?15.66% and positive deviation in D1cc of the spinal cord of 6.66%. There was no significant correlation between global GP (%) of 2D-PBD or 3D-MGR and the deviation of the most volumetric dosimetry parameters (DV or VD), when the Pearson's coefficient value of 0.8 was used for correlation evaluation. CONCLUSION:Even upon passing the pre-treatment phantom based dosimetric QA, there could still be risk of dose error like under-dose in PTVnx and overdose in critical structures. Measurement-guided 3D volumetric dosimetry QA is recommended as the more clinically efficient verification for the complicated NPC IMRT.

SUBMITTER: Sun WZ 

PROVIDER: S-EPMC5856312 | biostudies-literature | 2018 Mar

REPOSITORIES: biostudies-literature

altmetric image

Publications

Retrospective dosimetry study of intensity-modulated radiation therapy for nasopharyngeal carcinoma: measurement-guided dose reconstruction and analysis.

Sun Wen-Zhao WZ   Zhang Dan-Dan DD   Peng Ying-Lin YL   Chen Li L   Kang De-Hua DH   Wang Bin B   Deng Xiao-Wu XW  

Radiation oncology (London, England) 20180315 1


<h4>Background</h4>Conventional phantom-based planar dosimetry (2D-PBD) quality assurance (QA) using gamma pass rate (GP (%)) is inadequate to reflect clinically relevant dose error in intensity-modulated radiation therapy (IMRT), owing to a lack of information regarding patient anatomy and volumetric dose distribution. This study aimed to evaluate the dose distribution accuracy of IMRT delivery for nasopharyngeal carcinoma (NPC), which passed the 2D-PBD verification, using a measurement-guided  ...[more]

Similar Datasets

| S-EPMC6219576 | biostudies-literature
| S-EPMC5690083 | biostudies-other
| S-EPMC7065668 | biostudies-literature
| S-EPMC7715998 | biostudies-literature
| S-EPMC8214161 | biostudies-literature
| S-EPMC4642560 | biostudies-other
| S-EPMC5354909 | biostudies-literature
| S-EPMC4772023 | biostudies-other
| S-EPMC8351700 | biostudies-literature
| S-EPMC5642983 | biostudies-literature