Dosimetric advantages of O-ring design radiotherapy system for skull-base tumors.


ABSTRACT: The purpose of this study was to investigate whether a new O-ring design radiotherapy delivery system has advantages in radiotherapy planning for skull-base tumors. Twenty-five patients with skull-base tumors were included in this study. Two plans were made using conventional (Plan A) or new (Plan B) techniques. Plan A consisted of four dynamic conformal arcs (DCAs): two were horizontal, and the other two were from cranial directions. Plan B was created by converting horizontal arcs to those from caudal directions making use of the O-ring design radiotherapy system. The micromultileaf collimators were fitted to cover at least 99% of the planning target volume with prescribed doses, 90% of the dose at the isocenter. The two plans were compared in terms of target homogeneity, conformity, and irradiated volume of normal tissues, using a two-sided paired t-test. For evaluation regarding target coverage, the homogeneity indices defined by the International Commission on Radiation Units and Measurements 83 were 0.099 ± 0.010 (mean ± standard deviation) and 0.092 ± 0.010, the conformity indices defined by the Radiation Therapy Oncology Group were 1.720 ± 0.249 and 1.675 ± 0.239, and the Paddick's conformity indices were 0.585 ± 0.078 and 0.602 ± 0.080, in Plans A and B, respectively. For evaluation of irradiated normal tissue, the Paddick's gradient indices were 3.118 ± 0.283 and 2.938 ± 0.263 in Plans A and B, respectively. All of these differences were statistically significant (p-values < 0.05). The mean doses of optic nerves, eyes, brainstem, and hippocampi were also significantly lower in Plan B. The DCA technique from caudal directions using the new O-ring design radiotherapy system can improve target homogeneity and conformity compared with conventional DCA techniques, and can also decrease the volume of surrounding normal tissues that receives moderate doses.

SUBMITTER: Ogura K 

PROVIDER: S-EPMC5875486 | biostudies-literature | 2014 Mar

REPOSITORIES: biostudies-literature

altmetric image

Publications

Dosimetric advantages of O-ring design radiotherapy system for skull-base tumors.

Ogura Kengo K   Mizowaki Takashi T   Ishida Yuichi Y   Hiraoka Masahiro M  

Journal of applied clinical medical physics 20140306 2


The purpose of this study was to investigate whether a new O-ring design radiotherapy delivery system has advantages in radiotherapy planning for skull-base tumors. Twenty-five patients with skull-base tumors were included in this study. Two plans were made using conventional (Plan A) or new (Plan B) techniques. Plan A consisted of four dynamic conformal arcs (DCAs): two were horizontal, and the other two were from cranial directions. Plan B was created by converting horizontal arcs to those fro  ...[more]

Similar Datasets

| S-EPMC5377911 | biostudies-literature
| S-EPMC4899430 | biostudies-literature
| S-EPMC4110132 | biostudies-other
| S-EPMC4238033 | biostudies-literature
| S-EPMC10931115 | biostudies-literature
| S-EPMC6748853 | biostudies-literature
| S-EPMC6938502 | biostudies-literature
| S-EPMC7807648 | biostudies-literature
| S-EPMC7311828 | biostudies-literature
2021-11-03 | PXD025894 | Pride